6 Parameters
6.3 Operational data indicator
138
DC1 Frequency Inverter
10/12 MN04020003Z-EN
www.eaton.com
Example: Status displays
The status displays of the digital inputs and outputs are equivalent. They can
be used to check whether an output control signal (e.g. from an external con-
troller) activates the frequency inverter’s inputs (DI1 to DI4). This provides
you with an easy way to check the wiring (wire breakage).
The following table shows a few examples.
Display value:
•
1 = activated = High
•
0 = not activated = Low
P00-17
ro
0 - 2 x rated
operational
current
Motor current
The eight most recent values before the trip
Updated every 250 ms.
P00-18
15
ro
–
Software version
16
Version number and checksum
1 = I/O processor (on the left side)
2 = motor control
P00-19
ro
–
Serial number of frequency inverter
The frequency inverter
’
s unique serial number
Example: 540102 / 32 / 005
P00-20
12
ro
–
Frequency inverter part no.
13
Rated power of frequency inverter
14
Frequency inverter type (example: 0.37, 1 230, 3P-out)
PNU
ID
Access rights
Value
Description
DS
RUN
ro/rw
PNU
ID
Display value
Description
P00-04
11
0000
No digital input (DI1, DI2, DI3, DI4) is actuated
1000
Control signal terminal 2 actuated (DI1)
0100
Control signal terminal 3 actuated (DI2)
0010
Control signal terminal 4 actuated (DI3)
0001
Control signal terminal 6 actuated (DI4)
0101
Control signal terminals 3 and 6 actuated (DI2 + DI4)