EATON’s Crouse-Hinds Business

E

Bulkhead lighting fitting for hazardous areas for zone 2 / 22 
Serie: AB 05 Ex-nR

Technical data

1.1  AB 05 Ex-nR

EC type examination certificate

BVS 07 ATEX E151

Category of application acc to 94/9EG 
ATEX 
(special conditions see Fig. 3 tabelle 1)

D

 II 3 G Ex nR IIC  T... °C Gc 

D

 II 3 D Ex tc IIIC  IP66 T... °C Dc IP66

IEC Ex Certification of conformity

IECEx BVS 10.0071

Category of application acc to IEC Ex 
 
(special conditions see Fig. 3 tabelle 1)

Ex nR IIC  T... °C  Gc 
Ex tc IIIC  IP66 T... °C  Dc IP66

Protection acc. to IEC/EN 60529

IP 66

Lamps

Lampholder  E27 acc. to IEC/EN 60061-1

Insulation class acc to IEC/EN 61140

I

Max. permissible ambient temperature

Fig. 3 table 1

Rated voltage

up to 230 V AC/DC

Housing material

aluminium alloy pressure coating grey

Protection glas

Borosilikat

Storage temp. orig packing

-55 °C up to + 60 °C

Terminal capacity

1.5 mm² ... 4,0 mm²

Dimensions

see Fig. 2

Test torque
Cover bowl screws M8x40

10 Nm

Terminals

2.5 Nm

Cable entries (Ex-e)

M20 x 1.5 (Ø 7-13 mm)
M25 x 1.5 (Ø 10-15 mm)

suitable cables and test torques of the pressure srew
Cabel entry:

M20

M25

seel 1+2 
(Ø mm / Nm)    

1

2

min. 
max. 

(1)(2)

  7.0 / 1.5 
  9.0 / 1.4

10.0 / 2.3 
13.0 / 2.6

seel 2 
(Ø mm / Nm)    

1

2

min. 
max. 

(2)

  9.5 / 1.0 
13.0 / 1.7

13.5 / 1.5  
15.0 / 2.3

Test torque for screw in thread cable entry (Nm) 2.7

3.0

NPT Gewinde 1/2"
NPT Gewinde 3/4"

(Depend on ordernumber)
(observe operating instruction cable entries)
Temperature resistants see Fig. 3 Table 1

(1)

The tests of clamping ranges and torque values were performed with metal mandrel. The clamping range can 

vary by using cables with different manufacturing tolerances and material properties. Please use the 

combination of sealing 1 + 2 for the intermediate region. 

(2) 

When selecting the seal rubber, ensure that the pressure screw can be tightened when carrying out any 

future maintenance work on the cable entry.

Safety instructions 

a

The operations must be carried  
out by electrical suitably trained  
in hazardous area with knowledge 

of increased safty explosion protection  
IEC/EN 60079-14.

–  The light fitting is not suitable for use in 

hazardous areas of zone 0, 1and  20, 21 .

–  The requirements of the IEC/EN 60079-31 

regarding excessive dust deposits and  
temperature to be considered from the 
user.

–  The technical data indicated on the light 

fitting are to be observed!

–  Changes of the design and modifications 

to the light fitting are not permitted!

–  The light fitting shall be operated as 

intended and in undamaged and perfect 
condition!

–  Only genuine Cooper Crouse-Hinds (CCH)/

CEAG spare parts may be used for 
replacement!

–  Repairs may only be carried out by  

CCH/CEAG or a qualified “electrician”!

–  Observe the national safety rules and 

regulations for prevention of accidents and 
the following safety instructions which are 
marked with an (

a

) in these operating 

instructions!

–  Do not keep these operating instructions 

inside the light fitting during operation!

–  Observe the warning signs on the light 

fitting:

–  „Do not open when under voltage“.

–  „Wait 10 minutes before opening after 

switching off“

–  „Replace all seals after maintenance work“.

Conformity with standards

They have been designed, manufactured and 
tested according to the state of the art and to 
DIN EN ISO 9001:2008 and  
EN ISO/IEC 80079-34:2011.

The apparatus are conform to the standards 
specified in the EC-Declaration of conformity, 
enclosed separately.

Field of application

The light fitting is intended for use in potentially 
explosive atmospheres in zones 2 and zones 22 
in accordance with IEC/EN 60079-10-1 and  
IEC/EN 60079-10-2.

The light fitting can be used in inside- or  
outside to light areas with potentially explosive 
atmospheres.

5 Installation

5.1 General

For the mounting and operation, the respective 
national regulations as well as the general rules 
of engineering will have to be observed. 
(IEC/EN 60079-14)

The improper installation and operation of  
lights fittings may result in the invalidation 
of the guarantee.

Transport and storage only original packaging  in 
a closed and try room!

Observe far any cracks or damage in housing 
and glass! Don´t damage the fire-finish of  
the glass adquired during moulding (abrasions, 
sanding, etc.) that can weaking their mechani-
cal functions.

5.2 Mounting

Mounting dimensions: see Fig. 2 
Additional mounting material see CCH 
catalogue.

!

 For wall assembly cable entry from 

bottom.

Summary of Contents for GROUSE-HINDS AB 05 Ex-nR

Page 1: ...e AB 05 Ex nR Bulkhead lighting fitting for hazardous areas for zone 2 22 Serie AB 05 Ex nR Hublots pour atmosph res explosives les zones 2 22 S rie AB 05 Ex nR Betriebsanleitung Operating instruction...

Page 2: ...x nR IICT4 Gc D II 3 D Ex tc IIIC IP66T125 C Dc Gl hlampe 60W 60 60 55 55 55 Ta 40 D II 3 G Ex nR IICT4 Gc D II 3 D Ex tc IIIC IP66T125 C Dc Gl hlampe 60W 75 75 70 70 55 Ta 55 D II 3 G Ex nR IICT4 Gc...

Page 3: ...gesetzt werden Die Anforderungen der EN IEC 60079 31 u a in Bezug auf berm ige Staubablage rungen und Temperatur sind vom Anwender zu beachten Die auf der Leuchte angegebenen technischen Daten sind zu...

Page 4: ...sbruch der Lampe beim Einschrau ben 5 6 Schlie en der Leuchte Alle Fremdk rper aus dem Ger t entfernen Auf den richtigen Sitz des Geh useoberteils und der Dichtungen achten Alle Dichtungen m ssen saub...

Page 5: ...Sie das Betriebsmittel vor dem ffnen oder vor Instandhaltungsarbeiten erst spannunsfrei ffnen und Schlie en der Leuchte siehe Abschnitt 5 4 Verwenden Sie nur Original ersatzteile Bei Sch den an dem G...

Page 6: ...r use in hazardous areas of zone 0 1and 20 21 The requirements of the IEC EN 60079 31 regarding excessive dust deposits and temperature to be considered from the user The technical data indicated on t...

Page 7: ...It must be ensured that during thigtening of the cap nut not the complete cable entry starts turning 5 3 1 nR Restricted breathing Zone 2 The Restricted breathing nR properties must be preserved when...

Page 8: ...is no explosive atmosphere when opening the equipment See section 5 4 for notes on opening and closing the lamp Only use original spare parts If the light fitting was previously in operation then wai...

Page 9: ...osph re explosive Ce luminaire ne convient pas a l emploi en atmosph re explosive de zones 0 1 et zones 20 21 Les exigences des CEI EN 60079 31 en ce qui concerne des d p ts de poussi re d mesur s et...

Page 10: ...Caract ristiques techniques Au cas o elles seraient forc es cela pourrait tre nuisible l indice de protection 5 3 Entr es de c ble a Les c bles et entr es de c ble doivent correspondre la r sistance...

Page 11: ...explosive est pr sente Mettez le mat riel avant de l ouvrir ou de travaux de maintenance spannunsfrei L ouverture et la fermeture de la lampe voir la section 5 4 Utilisez uniquement des pi ces de rech...

Page 12: ...Crouse Hinds CEAG estas instrucciones de servicio en otro idioma de la Union Europea EST Seda kasutusjuhendit oma riigikeeles v ite k sida oma riigis asuvast asjaomasest Cooper Crouse Hindsi CEAG esi...

Reviews: