5.2.3 Mounting on the column (optional)
When choosing the location of the column, consider a 300 mm free space requirement to the left and right sides of the
EV charger for air circulation.
Mounting the column to the concrete floor
Fix the column with 4 x M10 stainless steel threaded rods on a 400 mm x 700 mm x 150 mm concrete base. Use the
flat washers to secure the mounting.
The power input electrical cable is fed through the bottom-left opening of 100 mm x 50 mm.
Below is a schematic representation of the base of the EV charging station column to be mounted on the concrete
base.
Figure 12. The base of the charging station column with dimensions (mm)
350
50
100
120
200
235
540
ø16
ø40
700
115
400
200
Number Description
1
Concrete base
2
Floor-mounted column
3
Hole for electrical cables
A
Bottom view of the floor-mounted column
B
Bottom view of the concrete base
C
Overview of floor-mounted column on concrete base
A
B
C
3
3
2