background image

 

ExoCab34 outdoor cabinet 

User and Installation Guide 

 
 

©Eaton Corporation 2018. All rights reserved. 

Revision 0.1 

Page 31 of 35 

 

 

 

12.

 

Appendix D  ExoCab 34 outdoor enclosure datasheet 

 

 
 

The

 

Eaton

 

ExoCab34

 

outdoor

  

cabinet

  

belongs

 

to

 

a

 

range

 

of

 

versatile,

 

cost

 

effective

 

outdoor

 

cabinets

 

for

 

a

 

wide

 

range

 

of

 

electronics

 

applications.

 

 

The

 

ExoCab34

 

can

 

be

 

configured

 

for

 

DC

 

power,

 

UPS,

 

battery,

 

or

 

any

 

other

 

outdoor

 

installation

 

requiring

 

robust

 

protection

 

for

 

electronics

 

equipment.

 

 

Front

 

and

 

rear

 

doors

 

are

 

provided

 

for

 

ease

 

of

 

access.

 

Cooling

 

options

 

include

 

unvented,

 

fresh

 

air

 

cooled,

 

heat

 

exchanger

 

and

 

air

 

conditioned.

 

 

The

 

Cab34

 

includes

 

a

 

200mm

 

plinth

 

and

 

lifting

 

eyes.

 

It

 

is

 

constructed

 

from

 

marine

grade

 

aluminium

 

and

 

stainless

 

steel

 

for

 

long

 

life

 

in

 

harsh

 

environments.

 

When

 

fitted

 

with

 

Eaton

 

DC

 

power

 

equipment

 

or

 

UPS

 

,

 

full

 

remote

 

monitoring

 

by

 

web

 

/

 

SNMP

 

is

 

provided.

 

 

 

Versions 

1.

 

Standard,

 

closed

 

enclosure

 

A

 

sealed

 

enclosure

 

for

 

equipment

 

with

 

small

 

heat

 

dissipation

 

requiring

 

a

 

high

 

level

 

of

 

protection

 

from

 

the

 

environment.

 

 

2.

 

Fresh

air

 

cooled

 

Fresh

 

air

 

cooling

 

allows

 

a

 

much

 

higher

 

heat

 

dissipation.

 

For

 

robust

 

/

 

hardened

 

equipment.

 

 

3.

 

Heat

 

exchanger

 

Provides

 

a

 

high

 

degree

 

of

 

environmental

 

protection

 

with

 

increased

 

dissipation

 

relative

 

to

 

the

 

sealed

 

unit.

 

Very

 

low

 

maintenance.

 

 

4.

 

Air

 

conditioned

 

Provides

 

a

 

high

 

degree

 

of

 

environmental

 

protection

 

with

 

high

 

heat

 

dissipation

 

and

 

wide

 

operating

 

temperature

 

range.

  

 

Other

 

versions

 

to

 

special

 

order.

 

 

Features 

 

UPS,

 

DC

 

power,

 

battery

 

and

 

other

 

equipment

 

options

 

 

34U

 

of

 

equipment

 

space

 

 

Sealed,

 

fresh

 

air,

 

heat

 

exchanger

 

and

 

air

 

conditioned

 

options.

 

 

Cost

 

effective

 

 

High

 

level

 

of

 

protection

 

from

 

the

 

environment

 

 

Durable

 

aluminium

 

exterior

 

and

 

stainless

 

steel

 

internal

 

parts.

 

 

Three

point

 

locking.

  

 

Lock

 

to

 

customer

 

requirements,

 

including

 

triangle

 

key,

 

lock

 

barrels

 

compatible

 

with

 

other

 

Eaton

 

cabinets,

 

etc.

 

 

Anti

graffiti

 

finish

 

 

Summary of Contents for ExoCab34

Page 1: ...USER S AND INSTALLATION GUIDE ExoCab34 Outdoor Enclosure...

Page 2: ...for future reference The contents of this manual are the copyright of the publisher and may not be reproduced even extracts without the written approval of Eaton Corporation Every care has been taken...

Page 3: ...equipment 16 4 2 Cautions 16 5 Install cabinet 16 5 1 Overview of tasks 16 5 2 Concrete foundation 16 5 3 Place cabinet 19 5 4 Fit air conditioner roof if required 20 5 5 Fit heat exchanger door if r...

Page 4: ...ium level of risk which if not avoided could result in serious injury or death or damage to your machine CAUTION CAUTION indicates a hazard with a low level of risk which if not avoided could result i...

Page 5: ...ls are used to indicate an action that must be taken General symbol for mandatory action Disconnect from power source Read the manual or instructions 1 3 Conventions used in this document This documen...

Page 6: ...ormed by a service engineer from the manufacturer or from an agent authorized by the manufacturer WARNING The UPS is powered by its own energy source batteries The output terminals may be energized ev...

Page 7: ...y opening the corresponding battery circuit breaker Check if the battery is inadvertently grounded If it is remove the source of the ground Contacting any part of a grounded battery can cause a risk o...

Page 8: ...s People who plan and perform the installation of the ExoCab34 People who use the ExoCab34 This document provides guidelines for how to install commission and operate the ExoCab34 and a UPS installed...

Page 9: ...ir cooled heat exchanger and air conditioned The ExoCab34 includes a galvanised steel or aluminium mounting plinth and lifting eyes The cabinet is constructed from marine grade aluminium and stainless...

Page 10: ...e Low cost Air filter provides some protection against environmental contaminations The filter requires periodic cleaning and replacement Recommended for clean environments or with hardened equipment...

Page 11: ...1 Page 11 of 35 3 4 Battery cooling Where batteries are installed they may be separated from the main equipment compartment The batteries may be cooled by a door mounted TEC cooler 3 5 Exploded views...

Page 12: ...cabinet User and Installation Guide Eaton Corporation 2018 All rights reserved Revision 0 1 Page 12 of 35 Figure 2 Exploded views Heat exchanger Air conditioner Door or optional rear cover Door or opt...

Page 13: ...19 inch equipment rails Full height 19 inch equipment mounting 34U is available for standard 19 inch equipment mounting Split cabinet equipment mounting Equipment requiring different environments can...

Page 14: ...Eaton Corporation 2018 All rights reserved Revision 0 1 Page 14 of 35 3 7 Cabinet Equipment Mounting Dimensions Top View cross section of cabinet Full Cabinet Front View Split Cabinet Front View Cabl...

Page 15: ...nted These vary according to the cabinet options Vented Side Section view Keep 20mm mm front and rear clear for ducting Heat exchanger Side Section view Keep 2U at the top clear Keep 125 mm at the fro...

Page 16: ...te foundation See details on page 16 2 Bolt down Cabinet See details on page 19 3 Fit air conditioner roof if required See details on page 20 4 Fit heat exchanger door if required See details on page...

Page 17: ...ights reserved Revision 0 1 Page 17 of 35 Top view Door opening space required Top view Plinth section bolt down holes Figure 4 Installation clearances Standard and Fresh Air Cooled Air Conditioned He...

Page 18: ...ny expected flood water Step 4 Install duct pipes Specific design details for the base are not given here because of varying site conditions and seismic restraint requirements In general the base must...

Page 19: ...ectrolytic corrosion Procedure complete 5 3 Place cabinet Step 1 Lift and position cabinet 1 Check that the base is clean and the bolt down sockets are free of debris 2 Lift the cabinet minus batterie...

Page 20: ...mounting plate front and rear with the 4 x M6 fasteners supplied 5 5 Fit heat exchanger door if required 1 Open Door 2 Remove circlips from hinge pins 3 Remove hinge pins IMPORTANT to support door 4 R...

Page 21: ...on battery installation The following are recommended Battery Installation Practices These supplement the specific installation instructions of the relevant battery manufacturer Battery Installation...

Page 22: ...All panels are in place The cabinet interior is clean and all work debris has been removed 7 2 Apply AC Power A registered electrician or suitably qualified person must check the integrity of the inst...

Page 23: ...n LED is off Fan dc supply is off Check fan dc supply is 48 54V Fan controller faulty Replace faulty fan controller see details on 23 Fan Fail alarm and or fan controller alarm LED on LED on fan s fau...

Page 24: ...an controller 1 Label then disconnect all wires 2 Connect all wires to the new fan controller 3 Fit the new controller into the cabinet Step 5 Switch on supply 1 Switch on the AC power to the cabinet...

Page 25: ...rnal cover mounting screws Remove external heat exchanger cover fasteners inside of door Once the internal fasteners are removed use a sharp knife to cut the sealant around the cover Remove the old se...

Page 26: ...erved Revision 0 1 Page 26 of 35 Internal fan access Remove top duct Remove heat exchanger access panel Remove fan attached to mounting bracket Remove fan 1 Remove duct 2 Remove cover 3 Remove fan and...

Page 27: ...ing to insulate the connections Step 4 Fit new fan Reverse the removal process shown in Step 2 After refitting the External cover apply sealant to the top and sides use a clear neutral cure silicone s...

Page 28: ...tion Guide Eaton Corporation 2018 All rights reserved Revision 0 1 Page 28 of 35 9 Appendix A 93PS20 93PS40 UPS options 9 1 Layout Refer also to the appropriate UPS User s and Installation Guide suppl...

Page 29: ...Installation Guide Eaton Corporation 2018 All rights reserved Revision 0 1 Page 29 of 35 10 Appendix B 9PX UPS option Refer also to the appropriate UPS User s and Installation Guide supplied separatel...

Page 30: ...b34 outdoor cabinet User and Installation Guide Eaton Corporation 2018 All rights reserved Revision 0 1 Page 30 of 35 11 Appendix C Wiring diagrams 11 1 ExoCab34 with heat exchanger door or air condit...

Page 31: ...onitoring by web SNMP is provided Versions 1 Standard closed enclosure A sealed enclosure for equipment with small heat dissipation requiring a high level of protection from the environment 2 Fresh ai...

Page 32: ...ExoCab34 outdoor cabinet User and Installation Guide Eaton Corporation 2018 All rights reserved Revision 0 1 Page 32 of 35...

Page 33: ...and rear of cabinet Temperature ratings Closed enclosure Heat dissipation Maximum 200W Internal temperature rise 10 C for 100W internal dissipation 20 C for 200W internal dissipation Temperature rati...

Page 34: ...ExoCab34 outdoor cabinet User and Installation Guide Eaton Corporation 2018 All rights reserved Revision 0 1 Page 34 of 35 13 Appendix E Concrete plinth drawing...

Page 35: ...ia Eaton Industries 10 Kent Road Mascot 2020 NSW Australia T 1300 877 877 E aupqsales eaton com New Zealand Eaton Industries Company 106 Wrights Road Christchurch 8041 NZ T 03 335 3126 E nzorders eato...

Reviews: