4 Wiring with
4.10 Timing Relay
Operating instructions
05/10 MN05013003Z-EN
www.eaton.com
133
4.10.6.2 Example: timing relay, off-delayed
The off-delayed function is used to implement a rundown time on the
conveyor if required.
4.10.6.3 Example: timing relay, on- and off-delayed
The on/off-delayed function is used to implement the delay of both the
startup and the disconnection if required.
4.10.6.4 Example: timing relay, single pulse
The input pulses present may vary in length. These pulses must be
normalized to the same length. The Single pulse function can be used very
simply to implement this.
4.10.6.5 Example: timing relay, flashing
This example shows a continuous flash pulse function. Outputs Q3 or Q4
flash according to the marker states of M8 or M9.
Circuit diagram display
Parameter settings of timing relay T2
I6-------TT2
T2-------
Ä
Q2
T2
â
S
+
I1 30,000
I2
Circuit diagram display
Parameter settings of timing relay T3
I6-------TT3
T3-------
Ä
Q3
T3 X
â
S +
I1 10,000
I2 30,000
Circuit diagram display
Parameter settings of timing relay T4
I7-------TT4
T4-------
Ä
Q4
T4
ü
S
+
I1 10,000
I2
Circuit diagram display
Parameter settings of timing relay T5
---------DD5
T5
u
M8----
Ä
Q3
h
M9----
Ä
Q4
T5
Ü
S +
I1 02,000
I2 01,000