4 Wiring with
4.10 Timing Relay
124
Operating instructions
05/10 MN05013003Z-EN
www.eaton.com
4.10.2 Retention
Timing relays can be run with retentive actual values. Select the number of
retentive timing relays in the SYSTEM…
→
RETENTION… menu.T7, T8, T13
to T16 can be used as retentive timing relays.
If a timing relay is retentive, the actual value is retained when the operating
mode is changed from RUN to STOP and when the power supply is switched
off.
When easy is restarted in RUN mode, the timing relay continues with the
retentively stored actual value.
4.10.3 Timing relay modes
Mode, time base
Time setpoint 1
Time setpoint 2
Actual value of elapsed time
#
Contact has not switched.
â
Contact has switched.
T1 X
S +
I1 10,000
I2 00.00
#
T:03.305
→
When easy is restarted, the status of the trigger pulse must be
the same as on disconnection.
Status 1 with all operating modes:
•
On delayed,
•
Single pulse,
•
Flashing.
Status 0 with all operating modes: off-delayed.
Status 1 or 0 (as with disconnection): on-delayed: on/off-delayed
Parameters
Switch function
X
On-delayed switching
?X
On-delayed switching with random time range
â
Off-delayed switching
?
â
Off-delayed switching with random time range
X
â
On- and off-delayed, two time setpoints
?X
â
On- and off-delayed switching with random time, 2 time setpoints
ü
Single pulse switching
Ü
Flash switching, mark-to-space ratio = 1:1, 2 time setpoints
Ü
Flash switching, mark-to-space ratio = 1:1, 2 time setpoints