4 Wiring with
4.15 Circuit examples
Operating instructions
05/10 MN05013003Z-EN
www.eaton.com
161
Figure 89:
Stairwell lighting with easy
Button pressed briefly
Light ON or OFF. The impulse relay function will even switch off Continuous lighting.
Light off after 6 min. with Continuous lighting this function is not active.
Button pressed for more
than 5 s
continuous light
N
L
S1
S2
S3
E1
E2
E3
1
2
Q1
I1
L N
Summary of Contents for easy500, easy700
Page 4: ...II...
Page 28: ...1 1 5 operating principles 24 Operating instructions 05 10 MN05013003Z EN www eaton com...
Page 210: ...7 What Happens If 7 3 Event 206 Operating instructions 05 10 MN05013003Z EN www eaton com...
Page 234: ...9 Glossary of terms 230 Operating instructions 05 10 MN05013003Z EN www eaton com...