9
XSTORAGE HOME POWER METERS MANUAL
MN700001EN March 2019 www.eaton.com/xstorage
Figure 17: SFERE power meter wiring terminals
The hybrid inverter RS-485 port terminals are located in the
communication slot that is highlighted by the arrow pointer in
Figure 18. Please note that up to two devices (in this case, two
power meters) can be connected through the hybrid inverter’s
RS-485 port.
Figure 18: Connection of the RS845 terminal block
connector to the RS-485 port of the hybrid inverter
The wiring of the RS-485 port terminals of the hybrid inverter
and the power meters terminals is illustrated in Figure 19:
•
Connect the RS-485 terminals of the power meter to
the RS-485 terminal block using a 1 mm
2
cable, which
is included in the accessory box kit provided with the
xStorage Home system and described in the xStorage Home
installation manual;
•
The connection to the RS-485 connection port of the hybrid
inverter should be realized via the RS-485 terminal block.
Figure 19: Wiring the hybrid inverter and the power meters
via the RS-485 port
Figure 20: RS-485 connector terminals
The design of the RS-486 connector terminals is illustrated in
Figure 20.