INSTALLATION INSTRUCTIONS/WIRING
14
PANEL MOUNTING
The panel mounting kit includes: (1) mounting gas-
ket, (2) mounting clips and (2) screws. Refer to the
dimension diagram in Figure 5 for a drawing of the
correct installation of these parts.
The mounting gasket is coated on one side with a
contact adhesive and a paper backing. Care
should be taken during the gasket installation that
the gasket be correctly positioned on the panel at
the first attempt. Attempting to re-position the gas-
ket once the adhesive has come in contact with
the panel is likely to deform or tear the gasket.
This may result in an improper seal. For best
results, follow these directions:
1. Stand the counter on a desk or table with its
display down, screw terminals up.
2. Remove and discard the center square of the
gasket at the scribe marks in the gasket and
paper backing. Do not remove the backing
from the remaining outer rim.
3. Slide the gasket down the unit until it is in posi-
tion at the rear of the unit’s front bezel. The
paper backing side should be up.
4. Insert the tip of a knife between the paper and
the gasket and, while holding the gasket down
to the unit with the knife, peel off the paper
backing.
5. Slide the unit through the panel cutout until the
gasket firmly adheres to the panel.
6. Install the mounting clips and screws as
shown in the diagram above. Do not over
tighten the mounting screws. The screws
should be tight enough to firmly hold the unit in
place, but not so tight as to squeeze the gas-
ket out from behind the front bezel.
7. A switch shall be included in the building
installation:
•
It shall be in close proximity to the equip-
ment and within easy reach of the opera-
tor.
•
It shall be marked as the disconnecting
device for the equipment.
•
Switches and circuit breakers in Europe
must comply with IEC 947.
Figure 8.
115 VAC 47/63 Hz Power Connection