SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
IF 1753
Champ® LED Floodlight
PFM Series LED Fixtures Gen. II
Installation & Maintenance Information
IF 1753 • 04/22 Copyright
®
2022, Eaton’s Crouse-Hinds Division
Page 1
WARNING
To avoid the risk of fire, explosion or electric shock,
this product should be
installed, inspected and maintained by a qualified electrician only, in accordance
with all applicable electrical codes.
WARNING
To avoid electric shock:
•
Be certain electrical power is OFF before and during installation and
maintenance.
•
Floodlight must be supplied by a wiring system suitable per local code
with an equipment grounding conductor.
To avoid burning hands:
•
Make sure LEDs and drivers are cool to touch when performing
maintenance.
WARNING
To avoid explosion:
•
Make sure the supply voltage is the same as the rated floodlight voltage.
•
Do not install where the marked operating temperatures exceed the
ignition temperature of the hazardous atmosphere.
•
Do not operate in ambient temperatures above those indicated on the
floodlight nameplate.
•
Use only replacement parts from Crouse-Hinds.
•
Use proper supply wiring as specified on the floodlight nameplate.
•
All surfaces must be clean.
•
Before opening, electrical power to the floodlight must be turned off and
area must be free from hazardous atmosphere. Keep tightly closed when
in operation.
APPLICATION
Champ
®
LED Floodlights are suitable for use in the following ordinary (unclassified)
locations as defined by the National Electrical Code (NEC
®
):
PFM:
• Wet Location, Type 4X
UL Standards:
• UL1598 Luminaires, UL1598A Marine, UL8750
CSA Standard:
• CSA C22.2 No. 250
IEC Standards:
• IEC 60598-1:2008/EN60598-1:2008
• IEC 60598-2:2008/EN60598-2:2008
•
Refer to the floodlight nameplate for specific maximum ambient temperature suitability
and corresponding minimum supply conductor temperature.
Champ
LED Floodlight construction is designed for use indoors and outdoors in marine
and wet locations, where moisture, dirt, corrosion, vibration and rough usage may be
present.
Champ LED Floodlights are supplied for use with a choice of voltages
:
• 100-277 VAC, 50/60Hz
• 108-250 VDC
• 347-480 VAC, 50/60Hz
Champ LED Floodlights for IEC:
• 100-252 VAC, 50/60 Hz, 2.16
• 111-227 VDC
• 385-436 VAC, 50/60 Hz
Figure 1
Figure 2
INSTALLATION
Mounting
Yoke Mount - Wall Mount Using Floodlight Yoke Only
1.
Using floodlight yoke as a template, mark and drill desired location on mounting
surface.
2.
Secure floodlight yoke to surface using ½” bolts or lag screws (not provided).
WIRING
Wiring the Floodlight
1.
Open back cover/heat sink by loosening nine (9) #10-24 x 0.75” stainless steel
cover bolts using a 5/8” nut socket or flat head screwdriver (see Figure 1). The
(see Figure 1). The
heat sink cover should be removed by pulling back on one corner of the top
heat sink cover should be removed by pulling back on one corner of the top
most edge to prevent damage to gasket.
most edge to prevent damage to gasket.
2.
All components in the fixture are pre-wired so only line in, neutral and ground
need to be connected in the fixture using the terminal block using methods that
comply with all applicable codes. Insert wires into terminal block by pressing
down on tabs. Be sure wires are spaced as shown in Figure 2.
•
Wire range from AWG 20-12 (0.5-3.3mm
2
).
•
Entries to driver housing shall be sealed with devices rated a
minimum of IP66.
•
Standard openings are 3/4 NPT.
•
Optional openings are M20 (20mm) and/or M25 (25mm).
0359
DO NOT PLACE
ADDITIONAL WEIGHT
ON THE BACK COVER/
HEAT SINK
Directive EU 2019/2015
This product contains a light source of energy efficiency class D or E.