background image

The instructions in this manual are not intended as a 

substitute for proper training or adequate experience in the 

safe operation of the equipment described. Only competent 

technicians who are familiar with this equipment should 

install, operate, and service it.
A competent technician has these qualifications:
• Is thoroughly familiar with these instructions.
•  Is trained in industry-accepted high and low-voltage safe 

operating practices and procedures.

•  Is trained and authorized to energize, de-energize, clear, 

and ground power distribution equipment.

•  Is trained in the care and use of protective equipment 

such as arc flash clothing, safety glasses, face shield, hard 

hat, rubber gloves, clampstick, hotstick, etc.

Following is important safety information. For safe 

installation and operation of this equipment, be sure to read 

and understand all cautions and warnings.

Safety instructions

Following are general caution and warning statements that 

apply to this equipment. Additional statements, related 

to specific tasks and procedures, are located throughout 

the manual.

Safety for life

!

SAFETY

FOR LIFE

!

SAFETY

FOR LIFE

Eaton’s Cooper Power series products meet or exceed all applicable industry standards relating to product safety. We 

actively promote safe practices in the use and maintenance of our products through our service literature, instructional 

training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing, 

and service.
We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around 

high voltage lines and equipment, and support our “Safety For Life” mission.

Safety information

DANGER

Hazardous voltage . Contact with hazardous voltage will 

cause death or severe personal injury . Follow all locally 

approved safety procedures when working around 

high- and low-voltage lines and equipment . 

G103 .3

WARNING 

Before installing, operating, maintaining, or testing this 

equipment, carefully read and understand the contents 

of this manual . Improper operation, handling or 

maintenance can result in death, severe personal injury, 

and equipment damage . 

G101 .0

WARNING 

This equipment is not intended to protect human 

life . Follow all locally approved procedures and safety 

practices when installing or operating this equipment . 

Failure to comply can result in death, severe personal 

injury and equipment damage . 

G102 .1

WARNING 

Power distribution and transmission equipment must 

be properly selected for the intended application . It 

must be installed and serviced by competent personnel 

who have been trained and understand proper safety 

procedures . These instructions are written for such 

personnel and are not a substitute for adequate training 

and experience in safety procedures . Failure to properly 

select, install or maintain power distribution and 

transmission equipment can result in death, severe 

personal injury, and equipment damage . 

G122 .3

This manual may contain four types of hazard statements:

DANGER 

Indicates an imminently hazardous situation which, if 

not avoided, will result in death or serious injury .

WARNING 

Indicates a potentially hazardous situation which, if not 

avoided, could result in death or serious injury .

 CAUTION 

Indicates a potentially hazardous situation which, if not 

avoided, may result in minor or moderate injury .

 CAUTION

Indicates a potentially hazardous situation which, if not 

avoided, may result in equipment damage only .

Hazard Statement Definitions

iii

OPERATION INSTRUCTIONS

   MN280051EN   May 2017

Summary of Contents for COOPER POWER 4E

Page 1: ...Types E 4E V4E H 4H V4H L and V4L single phase recloser installation and operation instructions COOPER POWER SERIES Reclosers MN280051EN Effective May 2017 Supersedes April 2014 S280 10 8...

Page 2: ...OSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT SHALL NO...

Page 3: ...aracteristics 2 Data plates 3 Manual operating levers and indicators 3 Manual operating handle 3 Non reclosing lever 3 Operations counter 3 RATINGS AND SPECIFICATIONS 4 DIMENSIONS AND WEIGHTS 6 INSTAL...

Page 4: ...Life mission Safety information DANGER Hazardous voltage Contact with hazardous voltage will cause death or severe personal injury Follow all locally approved safety procedures when working around hig...

Page 5: ...mize the possibility of mechanical damage particularly to the bushings Standards Eaton s Cooper Power series reclosers are designed and tested in accordance with the following standards ANSI IEEE C37...

Page 6: ...maximum of four operations When a recloser is programmed for both fast and delayed operations the fast operations involving no intentional time delay occur first in the sequence according to the reclo...

Page 7: ...located under the sleet hood See Figure 3 WARNING Hazardous voltage This device is not a substitute for a visible disconnect Follow all locally approved safety practices Failure to follow proper safet...

Page 8: ...280 V4L 14 4 15 5 110 50 45 280 Table 2 Rated interruptions Recloser type Interrupting rating Maximum circuit X R ratio Number unit operations Total unit operations E 15 20 2 40 72 45 55 5 20 90 100...

Page 9: ...2000 70 140 2800 2500 2000 100 200 3000 2500 2000 V4H 5 10 200 200 200 10 20 400 400 400 15 30 600 600 600 25 50 1000 1000 1000 35 70 1400 1400 1400 50 100 2000 2000 2000 70 140 2800 2500 2000 100 20...

Page 10: ...POLE BOLT A G Figure 7 Dimensions of types E 4H and L reclosers Table 5 Recloser dimensions Description Recloser type E mm in 4E V4E mm in 4H V4H mm in L mm in V4L mm in A 380 15 380 15 355 14 380 15...

Page 11: ...yed operations a short time elapses between opening of contacts and placement of the operating handle in the OPEN position 5 Check data plates Make sure the ratings and settings on the recloser data p...

Page 12: ...recloser operation The recloser can be opened or closed manually regardless of the position of the non reclosing lever Figure 8 Connection diagram with switches to facilitate maintenance and complete...

Page 13: ...rs For further information contact your Eaton representative Factory maintenance classes The factory service department offers recloser maintenance training classes These classes taught by experienced...

Page 14: ...This page is intentionally left blank 10 Types E 4E V4E H 4H V4H L and V4L single phase recloser installation and operation instructions OPERATION INSTRUCTIONS MN280051EN May 2017...

Page 15: ...This page is intentionally left blank 11 Types E 4E V4E H 4H V4H L and V4L single phase recloser installation and operation instructions OPERATION INSTRUCTIONS MN280051EN May 2017...

Page 16: ...tes Eaton com cooperpowerseries 2017 Eaton All Rights Reserved Printed in USA Publication No MN280051EN May 2017 KA2048 0348 REV03 Eaton is a registered trademark All trademarks are property of their...

Reviews: