40
CMA USER MANUAL
E-VLMB-TT005-E April 2019 www.eaton.com
CMA User Manual
If mode 1 is: Twin spool flow - UFC
1
State
2: Zero Flow
3: Positive Flow - Decompression
4: Positive Flow - Passive
5: Positive Flow - Overrunning
6: Positive Flow - Pressure Limit
7: Negative Flow - Decompression
8: Negative Flow - Passive
9: Negative Flow - Overrunning
10: Negative Flow - Pressure Limit
11: Zero Flow Pressure Limit WP1
12: Zero Flow Pressure Limit WP2
3
Flow Demand [lpm x 8]
Shaped flow demand
If mode 1 is:
Twin spool pressure
(Delta p control)
1
state
0: Start-up
1: Delta P
2: Flow Limit
12
Delta Pressure Demand [cbar]
Differential pressure demand after limiting
13
Shaped Delta Pressure Demand [cbar] Pressure demand with a shaper applied
14
Delta Pressure [cbar]
Measured differential pressure
15
Delta Pressure Error [cbar]
Differential pressure error
20
Average Pressure Demand [cbar]
Average pressure demand after limiting
21
Average Pressure [cbar]
Measured average pressure
22
Average Pressure Error [cbar]
Average pressure error
Pressure control debug 1
1
Demand [cbar]
pressure demand
2
Shaped Demand [cbar]
Demand after a shaper applied
3
Pressure Error [cbar]
Pressure Error
12
Flow Demand [lpm x 1024]
Estimated Flow Demand
13
Position Demand [um]
Position Demand
15
Position Error [um]
position error
Position control debug 1
1
Control Side
0: Tank
1: Pressure
2: Center
12
Shaped Position Demand [um]
Position demand after a shaper is applied
17
Position Error [um]
Position error