CMA USER MANUAL
E-VLMB-TT005-E April 2019 www.eaton.com
CMA User Manual
7.2.2 Low level debug switch 1
Some of the settings in the Main Debug Switch list contain
a number of possible options for debug signals. Those
options are selected by the Low Level Debug Switches.
Low Level Debug Switch 1 and Low Level Debug Switch 2
are nearly identical, but there are a couple small differences.
Table 37 .
Input signal
processing debug1
4
CAN D Demand 1
Raw 12-bit demand 1 from the internal CAN
5
CAN D Demand 2
Raw 12-bit demand 2 from the internal CAN
8
CAN D Mode 1
Raw Mode 1 from the internal CAN
9
CAN D Mode 2
Raw Mode 2 from the internal CAN
10
Oil Compensated Temperature [C]
Temperature modified to adjust for viscosity of different oil types
11
Temperature [C]
Measured block temperature
Algorithm debug 1
If mode 1 is: Single spool flow
1
State
1: Flow
2: Pressure Limit
3: Zero Flow Pressure Limit
3
Input Demand [lpm x 8]
Input flow demand
4
Shaped Demand [lpm x 8]
Flow demand after applying a flow shaper
If mode 1 is: Single spool float
1
State
1: Flow control
2: PWM open to tank
If mode 1 is: Single spool pressure
1
State
1: Pressure
2: Flow Limit
If mode 1 is: Twin spool float
1
Combined state
1: Either WP1 or WP2 is in Flow
2: Both WP1 and WP2 are PWM open to Tank
4
WP1 State
1: WP1 in Flow
2: WP1 PWM open to Tank
If mode 1 is: Twin spool flow - IFC
1
state
0: Zero Flow
10: Positive Flow - Passive
11: Positive Flow - Overrunning
12: Positive Flow - Pressure Limit
13: Positive Flow - Anti-fallback
20: Negative Flow - Passive
21: Negative Flow - Overrunning
22: Negative Flow - Pressure Limit
23: Negative Flow - Anti-fallback
3
Flow Demand [lpm x 8]
Shaped flow demand