35
CMA USER MANUAL
E-VLMB-TT005-E April 2019 www.eaton.com
CMA User Manual
Event code
Description
Severity level
207
reported, if CV or PV replacement failed
Error/Event
208
reported, if a valve-block replacement failed
Error/Event
209
reported, if VSC replacement was not possible
Error/Event
210
Detected configuration is different than stored one
Error/Event
211
A data-section on the valve/VSC and its backup are corrupted
Error/Event
212
valve changed into safe state
Error/Event
213
at least one valve is not calibrated
Warning
214
at least one valve is not compatible with the SW-version of the VSC
Error/Event
215
at least one valve is not compatible with the OD-version of the VSC
Error/Event
216
daisy chaining proccess failed because of defect, wrong or unexistend cabling
Error/Event
217
serial number(s) within VSC NV and Valve DB has been updated because daisy chaining scanned serial number(s)
are differ to stored ones in valve DB
Information
218
valve ID(s) on valve have been updated because daisy chaining scanned valve ID(s) is different to stored one in valve DB
Information
219
scanned block IDs different to stored ones in valve DB, i.e. Layout Error-> Limp mode not possible
Information
220
during daisy chaining an error was detected
Error/Event
221
airbleeding was not successful
Warning
222
training was not successful
Warning
223
a training request was received, but denied, as CV is not trained
Warning
224
more than specified valves (1CV, 15 PVs) are present, i.e. Layout Error-> Limp mode not possible
Error/Event
225
Daisy Chaining failed, because of Timeout Error, i.e. no valve is responding within daisy chaining timeout boundary
Error/Event
226
reassignment of Valve ID's caused by Valve/Block replacement
Error/Event
227
write finalize for reassigned Valve ID's caused by Valve/Block replacement failed
Error/Event
228
Daisy Chaining failed, because more than one CV's detected, i.e. Layout Error-> Limp mode not possible
Error/Event
229
old known valve layout is not scannable, e.g. some valves are missing or a daisy chain wire is broken
Error/Event
300
pressure sensor 1 malfunction detected
Error/Event
301
pressure sensor 2 malfunction detected
Error/Event
302
pressure sensor 3 malfunction detected
Error/Event
303
position sensor 1 malfunction detected
Error/Event
304
position sensor 2 malfunction detected
Error/Event
305
system temperature sensor reported an out of range value (<temp_min, >temp_max)
Error/Event
306
3.3V supply sensor reported an out of range value (<3V3_min, >3V3_max)
Error/Event
307
32V supply sensor reported an out of range value (<32V_min, 32V_max)
Error/Event
308
temperature sensor (pressure sensor 1) malfunction detected
Error/Event
400
short circuit on H-bridge
Error/Event
401
short of voice coil to chassis
Error/Event
600
VSC could not claim a valid addres for V2SI/J1939
Error/Event
601
A write request was attempted to a read-only value
Information
602
A write request was attempted to a (still) protected value
Information