Introduction
Eaton BladeUPS 12 kVA Maintenance Bypass Cabinet Installation and Operation Manual P-164000130—Rev 1
www.eaton.com/powerquality
1-5
CAUTION
l
Batteries can present a risk of electrical shock or burn from high short-circuit current. Observe
proper precautions. Servicing should be performed by qualified service personnel
knowledgeable of batteries and required precautions. Keep unauthorized personnel away from
batteries.
l
Replace batteries with the same number and type of batteries as originally installed in the UPS.
l
Proper disposal of batteries is required. Refer to local codes for disposal requirements.
l
Never dispose of batteries in a fire. Batteries may explode when exposed to flame.
l
Keep the UPS and MBC doors on and closed to ensure proper cooling airflow and to protect
personnel from dangerous voltages inside the unit.
l
Do not operate the UPS system close to gas or electric heat sources.
l
The operating environment should be maintained within the parameters stated in this manual.
l
Keep surroundings uncluttered, clean, and free from excess moisture.
l
Do not use this equipment for other than intended use.
l
Observe all DANGER, CAUTION, and WARNING notices affixed to the inside and outside of the
equipment.
CAUTION
The UPS system is designed for industrial or computer room applications, and contains safety
shields behind the front doors. However, the UPS system is a sophisticated power system and
should be handled with appropriate care.
1.4
Conventions Used in This Manual
This manual uses these type conventions:
l
Bold type
highlights important concepts in discussions, key terms in procedures, Web sites, and menu
options.
l
Italic type
highlights notes and new terms where they are defined.
l
Screen type
represents information that appears on the screen or LCD.
Icon
Description
NOTE
Information notes call attention to important features or instructions.
In this manual, the term UPS refers only to the UPS cabinet and its internal elements. The term UPS system
refers to the entire power protection system, including the UPS cabinet, the MBC, and options or accessories
that have been installed.
The term standalone refers to cabinets that are not physically attached to the UPS, and are wired with external
customer-supplied wiring.