71
Inertia Brake
6.
Apply contact lubrication to jumper harness per instructions in the “How to Apply Contact Lubrication to Eaton
Transmission Harnesses” section then connect the jumper harness to the transmission harness.
Reroute and reconnect the Transmission Harness to the Inertia Brake. Dress the harness along the transmission case
from the inertia brake up to the top of the transmission. Install the harness push-in anchor to the threaded-hole anchor
point in the inertia brake housing. Install tie wraps every 6-10 inches. The harness should not have sharp bends or be
under tension. See illustrations in the “How to Apply Contact Lubrication to Eaton Transmission Harnesses” section.
7.
Add UltraShift PTO Instruction Label to dash near PTO switch or a location in view of the driver.
8.
Install the PTO to the 8-bolt PTO opening following the manufacturers instructions.
Note:
Fill the transmission with lubricant.
Final Check
•
Make sure the mounting bolts are properly tightened.
•
Make sure the lubricant supply line is properly tightened.
•
Make sure the transmission is properly filled with lubricant.
•
Make sure the Transmission Harness is connected and locked.
•
Check for lubricant leaks after operating the vehicle.
•
Check that the inertia brake has sufficient clearance to prevent contacting tanks, brackets, frame rails, exhaust, or any
other part of the vehicle. Contacting anything when stationary or moving will cause damage to inertia brake, angle
adapter, or other vehicle equipment.
•
Instruct Driver on PTO operation with Fuller
®
UltraShift Transmissions.
Inertia Brake mounting to 6-bolt
opening as viewed from rear of
transmission
Note orientation of connector end of Inertia
Brake when directly mounted to 6-bolt
opening
Drawing shows Inertia Brake directly mounted to
the 6-bolt opening
Push-in harness anchor
point threaded hole.