32
PTO Interface
PTO Inte
rfac
e
UltraShift ASW Auto Neutral Feature
Electrical Interface Requirements
All devices mounted on the vehicle that require Auto Neutral function from the Fuller
®
UltraShift ASW transmission must provide
an electrical interface with the transmission. A switch must be used to activate the Neutral mode of the transmission. This feature
uses pin A1 and B1 of the 30-way push button connector. See the figure below for electrical interface diagram.
Features
When engaged (switch closed), this feature causes the transmission to neutralize when the vehicle is stopped (i.e. stationary PTO
operation) and a transmission gear engagement cannot be selected. When disengaged (switch opened), normal transmission
gear engagement can be selected.
The Fuller AutoShift ASW transmission must have an input signal from the device to activate this feature.
The input signal wires must be isolated from other related circuits.
S
witch
A1
A2
A3
B3
C1
C3
D1
D2
D3
E1
E2
E3
F1
F2
F3
G1
G2
G3
H1
H2
H3
B2
C2
J3
K3
J1
J2
K1
K2
FRONT VIEW
P
us
h B
u
tto
n
Co
n
t
r
ol (30-Way Co
nn
ecto
r
)
PACKARD
Co
nn
ecto
r
12048455
Te
r
mi
n
al 12103881
Pl
u
g
12034413
B1
A1
B1
Note:
The input signal wires for the Auto Neutral Device must be isolated from other related circuits.
Interconnection Table
FROM
TO
Description
A1
Switch
Auto Neutral Input
Switch
B1
Auto Neutral Return