Oslostrasse 5, CH
–
4023 Basel
Tel. +41 [0]61 333 70 33, Fax +41 [0]61 333 70 32
www.easyrain.net [email protected]
Brunner Bewässerung - Arrosage
Gebrauchsanweisung Steuerung ESP-TM
18
The ESP-TM controller is factory-supplied with a 3-Volt
lithium coin cell backup battery, which is wrapped in a
protective insulator strip in the battery drawer. This battery
is designed to maintain program information for several
days without power.
If electrical power to the ESP-TM remains uninterrupted,
the lithium coin cell will last well over one year. However,
long or frequent power interruptions will use up the battery
much faster.
To activate this battery, remove the lower face panel on the
controller and remove the plastic insulator strip from the battery.
Make sure battery drawer is completely closed, then reinstall
the lower face panel. See page 25 for complete instructions.
Install Battery
ESP-TM Installation and Operation
Page 33
Install Transformer
1
2
CAUTION:
DO NOT
plug the external transformer into
If your transformer has just two wires go to step 2.
If not, connect the green ground wire (which is the
longest wire) to the ground screw located just below
and to the right of the lower wall mounting screw.
If your transformer has just two wires
then a ground wire is not necessary.
See Note
Connect one pre-stripped transformer wire to each
of the flip strip terminals labeled 24VAC. Connect
either wire to either terminal; polarity of these wires
is not important.
into an electrical outlet until all other connections have
been made. In addition, connect the wires from the
transformer to the ESP-TM flip strip BEFORE plugging
in the transformer.
ESP-TM Installation and Operation