Page 33
Technical Documentation EASYRO
®
Water Treatment Systems© 2015 easymetal GmbH.
This information is subject to copyright laws and may not be reproduced or changed without express written permission of easymetal GmbH.
COMPLETING MAINTENANCE
Reinsert the power plug into the power socket (15).
Now the maintenance of the EASYRO
®
system is complete and standard operation continuous.
After the maintenance process, operating hours are reset to 4500 hours automatically.
The system starts in production mode (unless tank is full).
Dispose of all the remainder of the cleaning solution into the sewer and rinse the used canister
and both maintenance tubes to ready them for the next maintenance.
Now you have 4500 hours of operation available until the next maintenance is due (= six
months in continuous operation).
NO MAINTENANCE AVAILABLE
If you do not have a maintenance kit available, it is possible to delay the maintenance interval for
further 50 hours of production.
NOTE
This bridging should only be used in case of emergency! After these 50 hours of
production have elapsed, the EASYRO
®
system stops and cannot be restarted
until
serviced.
Please obtain your maintenance kit in time.
Bridging the maintenance for 50 hours of production:
Press the OK button to acknowledge the displayed “CHANGE FILTER.” The EASYRO
®
system now
continues in production mode for another 50 hours.
NOTE
After expiration of these 50 hours, the display shows
“ALARM STOP FILTER” (EMERGENCY STOP FILTER) and
only starts after carrying out the following steps:
Please press ESC + down arrow to reset the filter.
Prepare the maintenance kit and start the maintenance as described.
NOTE
If the following is displayed, maintenance cannot be carried until the error is
fixed: “Alarm Stop Filter”, “Motor-Temp Alarm”.
**********************
* ALARM STOP *
* FILTER *
2015 - 09 - 16
**********************
15