Please clean the union nut, sight glasses and gaskets of the pre-filter housings with lukewarm
water before reinserting the filter inserts.
If you have an activated carbon filter in chamber 1 and a sediment filter in chamber 2, please
replace both.
If you have a softener cartridge (transparent granulate) in chamber 1, please replace only the filter
insert in chamber 2. The granulate of the softener cartridge dissolves over time. It does not need
replacing until the granulate material is almost completely dissolved.
Nevertheless, please clean the filter housing and the inserts of both chambers with lukewarm
water.
Replace the gasket rings and screw down the union nut with the filter key.
Make sure the filter housings are tight and do not leak.
Rinse the pre-filter for 3 minutes.
Dispose the used filter insert from chamber 2 as normal household waste.
CHANGING THE FILTER IN THE PRE-FILTER HOUSING
While the cleaning solution is working in the membranes, please change the pre-filters in the
double filter housing.
Do so by unscrewing the union nut of the pre-filter housing with the included filter key and take
out the gasket rings.
!!! ATTENTION !!!
Both pre-filter housings are filled with water. Please use a bucket or a similar container to remove
the water.
Double filter housing
Activated carbon filter
Softener cartridge
8
Chamber 2
Chamber 1
Wound thread filter
Filter key