Technical Documentation EASYRO
®
Water Treatment Systems© 2015 easymetal GmbH.
This information is subject to copyright laws and may not be reproduced or changed without express written permission of easymetal GmbH.
EASYRO
Production
Con: 60
Maintenance: 3489
Control Elements and Keys
Left arrow
Right arrow
Down arrow
Up arrow
ESC
OK
This message appears when the water level of the tank has dropped
to 10 cm.
The system stops the production mode.
Please call our service team.
A lack of pressure occurred in the system.
The inlet pressure has dropped and the system stops the production
mode.
Possible measures:
1) Make sure the water supply is turned on
2) Check if maybe pre-filters are clogged (requires filter replacement)
3) Please disconnect and reconnect the power plug
If the inlet pressure continues to be low even after unplugging and
reconnecting the system, press ESC + right arrow for 2 seconds.
The display depicts “VENTING” and the system flushes for approx. 5
seconds.
Afterwards the system should then resume production mode.
IF NOT, please call our service hotline.
**********************
INPUT PRESSURE
**********************
**********************
CHECK
LEVEL
SENSOR
**********************
EASYRO
VENTING
APPENDIX
FAULTS AND TROUBLESHOOTING
Dislay color
Withe: System active
Yellow: Warning/Information
Red: Alarm