Page 32
Technical Documentation EASYRO
®
Water Treatment Systems© 2015 easymetal GmbH.
This information is subject to copyright laws and may not be reproduced or changed without express written permission of easymetal GmbH.
FLUSHING OUT THE CLEANING SOLUTION
After the residence time of the cleaning solution, please disconnect tubes from the plug
connection (9). This is done by pressing on the holding element and then pulling out one tube
after the other.
Now reinsert the water supply tube of the system into the connector of the pre-filter housing
(10). If you use the EASYRO
®
480 system, please reinsert both fresh water supplies back into
the corresponding connections of the system. Reopen the main water supply (11) and make
sure all tubes and connections are correctly positioned and do not leak.
Reinsert the power plug into the power socket and acknowledge with OK.
The system starts the flushing process and flushes the cleaning solution from the membranes
into the sewer.
9
11
10
Model
Flushing time
EASYRO
®
60/120
Min. of 3 minutes
EASYRO
®
240
Min. of 5 minutes
EASYRO
®
480
Min. of 10 minutes
12
After the flushing process, disconnect the power plug again (12).
RESTORING TO STANDARD OPERATION
Remove the tube of the clean water connector (13) and reinsert the tube leading to the tank
back into the clean water connector.
If necessary, set the mixture adjustment screw (14) back to its original position.
Mixture adjustment screw
Clean water connection
14
13