6.2 Service and Adjustment of Control Unit (Cont.)
17. Place compression spring and spring plate onto the end of the pincher plate
in recessed area, making sure the spring plate is 90 degrees from the control
tubes. Using (2) long adjustment bolts (washers next to head of bolt) carefully
thread each bolt evenly into the spring plate (spring plate recess area is to be
against spring, make sure spring is centered in recess areas on both plates).
18. Tighten the adjustment bolts evenly. MAKE SURE TO TURN EACH
BOLT ONE (1) TURN AND THEN THE OTHER SO AS TO ADJUST
THEM EVENLY – IT IS CRITICAL THAT THEY ARE ADJUSTED
EQUALLY- FAILURE TO ADJUST EQUALLY WILL DAMAGE THE
CONTROL UNIT.
Turn the bolts equally until the end of each bolt is 1” from the surface of the
spring plate (note: NOT from the weld nuts, but from the flat top surface of
the spring plate. This is the standard factory setting).