4.2 Loading Soda Blast Media (Cont.)
1. Turn off the safety lockout air valve located at the front of the pressure vessel
and lock it out. (sideways position)
TURN OFF THE SOURCE OF COMPRESSED AIR TO THE UNIT.
2. Vent the pressurized air from the delivery unit using the vessel valve located
on the top of the pressure vessel unit. Turn valve slowly (earplugs
recommended) releasing air pressure.
3. CHECK TO MAKE SURE SYSTEM IS TOTALLY DEPRESSURIZED.
4. CAREFULLY remove safety cap from pressure vessel media inlet fitting,
MAKING SURE ALL AIR IS DELETED FROM VESSEL.