Connecting the PROCESSOR
1C7836 – February 1996
27
Connecting the Water Supply
[1] Connect the main water supply to the WATER
SUPPLY INLET
3
/
8
in. female NPT COUPLING.
Note
• A mixing valve is not required for the PROCESSOR
if the incoming water temperature is between 4.4 -
32 C (40 - 90 F). However, tempered water is
recommended for mixing chemicals and cleaning
the TANKS of the PROCESSOR.
• The PROCESSOR has an internal 20 mm
(0.8 in.) water gap in the WASH RACK. A check
valve (or vacuum breaker) should not be
necessary; however, check and observe local
codes.
• The PROCESSOR accepts water pressure from
173 - 692 kPa (25 - 100 psi). Pressures above 692
kPa (100 psi) may cause the inlet solenoid to
malfunction. Increased noise levels may result in
the PROCESSOR if water pressure is in excess of
414 kPa (60 psi). If necessary, install a regulator
and set to 345 kPa (50 psi)
• A 50 micron filter is required (not supplied by
Kodak) in the input water line.
• An IRON PIPE is not recommended for the water
supply to the PROCESSOR.
H127_0079AA
H127_0079ACA
WATER
SUPPLY
INLET
H127_0080BA
Processor
close to
Locate Union
Processor
Water Supply
Hot and Cold
Shutoff Valve
FILTER (50 micron)
Part No. 458928
Thermometer
CHECK VALVE
processor)
cleaning
for
enough
(long
SERVICE HOSE
H127_0080BCA