Adjustments 23
To set AL-1 so the machine will shut down at 150°, press the left-arrow ( ) key and the
right-most digit will flash. Use the up- ( ) or down- ( ) arrow key to select the digit, and
then press the left-arrow ( ) key again. Use the up ( )- or down arrow ( ) key to set the
digit and repeat until the correct value is displayed. Press MD to lock in the setting.
9. Press MD and scroll through the menu until LOC is displayed.
10. Press the left-arrow ( ) key. (OFF will begin flashing.)
11. Press the up-arrow ( ) key. (OFF changes to ON, and ON is flashing.)
12. Press MD. (On stops flashing.)
13. Press and hold the MD key until PV and SV temperatures are displayed.
To Access Temperature Controller Menu Options
(ETC00011)
1. Press and hold the MD button and the up-arrow ( ) key for approximately 4 to 5
seconds until IN-T displays.
2. Press the MD button (do not hold it down) repeatedly to scroll through the menu.
3. When you have scrolled to the option to be changed, press the left-arrow key ( )
twice to select the option.
4. Press the up-arrow ( ) key to increase the value or the down-arrow ( ) key to
decrease the value.
5. Press MD and scroll through the menu until LOC is displayed to lock in the changed
value.
6. Press MD to return to normal display.
•
To unlock settings, scroll to LOC and press the left-arrow ( ) key twice, and then
press the ( ) down-arrow key.
•
To access the temperature controller second menu (Menu 2), press and hold MD
for approximately 4 to 5 seconds until Su-2 displays.
•
To return to the main menu (Menu 1), press and hold MD.
Refer to the Troubleshooting section of this User Guide for Temperature Controller