SET.RATIO
SET.RATIO is the page that allows you to calculate your count per weight ra o. The C/W Ra o,
or Count per Weight Ra o, is determined by the factory. This value is the divisor used to calcu
‐
late the engineering count (total) from the raw count. Your Full Scale value can be changed,
the units of your Full Scale value can be modi
fi
ed and the number and size of your Transducers
can be modi
fi
ed from this page. The bu on near the bo om will use this data and recalculate
your C/W ra o.
Engineering Count = Raw Count / Count per Weight Ra o
This data is set by the factory and should not be changed by the customer.