~ 6 ~
Chapter 3 Product Description
3.1 Product description
EAHI-6000-SL-S inverter is used to control and optimize the energy flow in the photovoltaic
system through an integrated energy management system. With the inverter, the power energy
generated in the photovoltaic system can be supplied for the load, stored in the battery, and
outputted to the grid. The inverter integrates with power supply, battery and Internet for
connection with grid, photovoltaic panels and the Internet of things to supply the power for
families, small supermarkets, farms and other places.
Product features:
Grid-tied & off-grid all-in-one machine
IP66 protection design
Up to 1.5 PV capacity ratio
Flexible operating mode setting
Remote intelligent monitoring
Integrated power battery stack design
Up to 6 x 100Ah cells stacked
3.2 Application scenarios
WARNING
The photovoltaic system is not suitable for connection with the devices requiring stable
power supply, such as life-sustaining medical devices. Make sure that no personal injury
is caused in case of system failure.
If the photovoltaic system is not equipped with a battery, it is not recommended to use the
BACK-UP function. The power consumption risk of the system caused therefore is
excluded from the warranty of the equipment manufacturer.
The battery current may be affected by some factors, such as temperature, humidity,
weather conditions, etc., which may cause battery current limit and affect carrying
capacity.
If overload protection is triggered on the inverter for single time, the inverter can be
restarted automatically; if overload protection is repeated, the restarting time of the
inverter will be prolonged. If it is required to restart the inverter as soon as possible, the
inverter may be restarted immediately by App.
If, during grid failure, load capacity is more than the rated power of the inverter, the
off-grid function of the inverter will be disenabled automatically; when the inverter is
restarted, close large load to ensure that the load power is less than the rated power of
the inverter.
The inverter has overload capacity and EPS function at the BACK-UP output port
(switching time <20ms), and may supply the power for normal use in ordinary domestic
load in case of grid failure. To ensure EPS switch over and power supply stability of the
Summary of Contents for EAHI-6000-SL-S