Note 1: If the battery is integrated with a readily accessible internal DC breaker, no additional
DC breaker is required.
Note 2: The recommended values in the table are for reference only. The actual values must
comply with local standard and actual conditions.
Note 3: The rated current of breaker
①
is suggested to lower than that of breaker
④
.
Note 4: If the rated current of on-site power cables are lower than those recommended above,
the breakers specification should be considered to match the power cables in first
priority.
Note 5: The AC port takes power from the grid and is set according to the grid circuit breaker.
Residual Current Monitoring Device
With an integrated universal current-sensitive residual current monitoring unit included, the
NO
Description
1
≤63A/230V/400V AC breaker
2
32A/230V/400V AC breaker
3
Depends on loads
4
Depends on household loads and inverter capacity
5
300mA RCD (Recommended)
6
30mA RCD (Recommended)