5 IMPORTANT INFORMATION REGARDING
REFRIGERANT USED
This product contains fluorinated greenhouse gases covered by the
Kyoto Protocol. Do not vent gases into the atmosphere.
Refrigerant type: R410A
GWP(1) value: 2088
(1) GWP = global warming potential
The refrigerant quantity is indicated on the unit name plate
6 SELECTING THE INSTALLATION SITE
■ Be sure to provide for adequate measures in order to prevent
that the unit be used as a shelter by small animals.
■ Small animals making contact with electrical parts can cause
malfunctions, smoke or fire. Please instruct the customer to keep
the area around the unit clean.
Make sure there is enough room to do the installation
f) Where voltage fluctuates a lot, such as in factories.
g) In vehicles or vessels.
h) Where acidic or alkaline vapors are present.
■ This appliance can be used by children 8 years old and above and
persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they are supervised or given
instruction on using the unit in a safe manner and understand the
hazards involved. Children should not play with the unit. Cleaning
and user maintenance should not be done by children without
supervision.
■ Children should be supervised to ensure that they do not play with
the appliance.
■ If the supply cord is damaged, it must be replaced by the manufaturer
or its service agent or a similarly qualified person.
■ DISPOSAL: Do not dispose this product as unsorted municipal
waste. Collection of such waste seperatelly for special treatment is
necessary.
Do not dispose of electrical appliances as municipal waste, use
seperate collection facilities.
Contact your local goverment for information regarding the
collection systems available.
If electrical appliances are disposed of in landfills or dumps,
hazardous substance can leak into the groudwater and get into the
food chain, damaging your health and well-being.
■
The
wiring must be performed by professional technicians in
accordance with national wiring regulation and this circuit diagram.
An all-pole disconnection device which has at least 3mm
seperation distance in all pole and a residualcurrent device(RCD)
with the rating not exceeding 30mA shall be incorporated in the
fixed wiring according to the national rule.
WARNING
1 Select an installation site where the following conditions
are satisfied and one that meets with your customer's approval.
- Places that are well-ventilated.
- Places where the unit does not disturb next-door neighbors.
- Safe places which can bear the unit's weight and vibration
and where the unit can be installed at an even level.
- Places where there is no possibility of flammable gas or product
leak.
- The equipment is not intended for use in a potentially explosive
atmosphere.
- Places where servicing space can be well ensured.
- Places where the units' piping and wiring lengths come within the
allowable ranges.
- Places where water leaking from the unit cannot cause damage
to the location (e.g. in case of a blocked drain pipe).
- Places where rain can be avoided as much as possible.
- Do not install the unit in places often used as a work space.
In case of construction work (e.g. grinding etc.) where a lot of dust
is created, the unit must be covered.
- Do not place any objects or equipment on top of the unit (top
plate)
- Do not climb, sit or stand on top of the unit.
- Be sure that sufficient precautions are taken in case of refrigerant
leakage according to relevant local laws and regulations.
2 When installing the unit in a place exposed to strong wind, pay
special attention to the following.
Strong winds of 5 m/sec or more blowing against the unit's air
outlet causes a short circuit (suction of discharge air), and this
may have the following consequences:
- Deterioration of the operational capacity.
- Frequent frost acceleration in heating operation.
- Disruption of operation due to rise of high pressure.
- When a strong wind blows continuously on the front of the unit,
the fan can start rotating very fast until it breaks.
3 Prepare a water drainage channel around the foundation, to drain
waste water from around the unit.
4 If water does not easily drain from the unit, mount the unit on a
foundation of concrete blocks, etc. (the height of the foundation
should be about 100 mm (3.93 in).
5 If you install the unit on a frame, please install a waterproof plate
(about 100 mm) on the underside of the unit to prevent water from
coming in from the low side.
6 When installing the unit in a place frequently exposed to snow,
pay special attention to elevate the foundation as high as possible.
.
■ Set the outlet side at a right angle to the direction of the wind.
Strong wind
Strong wind
Blown air
4
5/7/9 kW
B
A
5-9kW
Unit
B(mm)
1000
1500
10-16kW
5-9kW
Unit
A(mm)
300
300
10-16kW
In normal condition,refer to the figures below for installation of the
unit:
The position of barycenter for different unit can be seen in the
picture below.
10-16 kW
In case of strong wind and the wind direction can be foreseen,refer
to the figures below for installation of the unit(any one is OK):
■ Turn the air outlet side toward the building's wall, fence or screen.
V.2
Summary of Contents for ETH-80VM
Page 4: ...4 1 2 1 3 1 1 1 1 1 1 1 2 3 1 1 0 1 0 1 0 Forma Nombre V 2...
Page 7: ...NOTA NOTA NOTA 404 502 1210 361 760 1404 760 361 1404 100mm 80mm 7 kW 10 12 14 16 kW 7 V 2...
Page 49: ...50 11 PRUEBA DE FUNCIONAMIENTO Y COMPROBACI N FINAL V 2...
Page 50: ...51 NOTA V 2...
Page 56: ...57 Equipos Monof sicos 5 y 7kW ANEXO 1 ESQUEMA EL CTRICO UNIDAD INTERIOR V 2...
Page 57: ...58 Equipos Monof sicos 10 a 16kW V 2...
Page 86: ...60mm B C A 25 V 2...
Page 176: ...V 2 WIRE CONTROL WITH WEEKLY PROGRAMMING OWNER S MANUAL MODEL ECRTH...
Page 199: ...V 2 www easelectric es...