34
Procedure
1. Connect the cable to the appropriate terminals as shown in the
picture.
2. Fix the cable with cable ties to the cable tie mountings to ensure
stress relief
For room thermostat:
For booster heater:
For tank loop pump P_d and mix pump P_c:
Connection of the booster heater cable depends on the application.
Only when the domestic hot water tank is installed will this wiring be
needed. The unit only sends a turn on/off signal to the booster heater.
An additional circuit breaker is needed and a dedicated terminal is
needed to supply power to the booster heater.
See also "
8 Typical application examples
" and "
10.7 Field
settings/DHW control
” for more information.
P_c N
16
17
PUMPC
CONTROL SIGNAL OUTPUT
PUMPD
CONTROL SIGNAL OUTPUT
P_d N
29
30
TANK BOOST HEATER
CONTROL SIGNAL
OUTPUT
TBH N
4
5
For 5/7/9 kW unit
,
the terminal number
is 37 and 38.
NOTE
0.2A
Maximum running current
Wiring size
Voltage
220-240VAC
0.75mm
2
C
H
3
13
N
L
N
15
RT2
COOL
C
H
3
13
N
L
HEAT
N
15
C
H
3
13
N
15
C
H
3
13
N
15
N
L
N
L
C
H
3
13
N
L
N
15
C
H
3
13
N
L
N
15
N
L
Method A:
Method B:
Method C:
RT2
RT2
RT2
H
13
14
RT1
COOL
C
H
3
13
POWER IN
HEAT
L1
Method A:
Method B:
Method C:
H
13
14
RT1
C
H
3
13
POWER IN
L1
H
13
14
RT1
C
H
3
13
POWER IN
L1
RT1
POWER IN
External thermostat
External ON/OFF thermostat
Note:
there are two optional connect method depend on the room
thermostat type.
1. Room thermostat type 1(RT1): “POWER IN” provide the working
voltage to the RT, doesn’t provide the voltage to the RT connector
directly. Port “14 L1” provide the 220V voltage to the RT connector.
Port “14 L1” connect from the unit main power supply port L of 1-
phase power supply, L2 port of 3-phase power supply.
Method A
RT can control heating and cooling individually, like the controller for
4-pipe FCU. When the hydraulic module is connected with the
external temperature controller, user interface FOR SERVICEMAN
set THERMOSTAT and ROOM MODE SETTING to YES
:
A.1 When unit detect voltage is 230VAC between C and N ,the unit
operates in the cooling mode
A.2 When unit detect voltage is 230VAC between H and N, the unit
operates in the heating mode.
A.3 When unit detect voltage is 0VAC for both side(L-N, H-N) the unit
stop working for space heating or cooling.
A.4 When unit detect voltage is 230VAC for both side(L-N, H-N) the
unit working in cooling mode.
Method B
RT provide the switch signal to unit. user interface FOR
SERVICEMAN set ROOM THERMOSTAT and MODE SETTING to
YES
:
B.1 When unit detect voltage is 230VAC between H and N, unit turn
on.
B.2 When unit detect voltage is 0VAC between H and N, unit turn off.
Note
:
When ROOM THERMOSTAT is set to YES, the indoor
temperature sensor Ta can’t be set to valid, unit running only according
to T1.
Method C
Hydraulic module is connected with two external temperature
controllers, while user interface FOR SERVICEMAN set DUAL
ROOM THERMOSTAT to YES,
C.1 When unit detect voltage is 230VAC between H and N ,the MAIN
side turn on.When unit detect voltage is 0VAC between H and N, the
MAIN side turn off.
C.2 When unit detect voltage is 230VAC between C and N, the ROOM
side turn on according to climate temp curve. When unit detect voltage
is 0V between C and N), the ROOM side turn off.
C.3 When H-N and C-N are detected as 0VAC, unit turn off.
C.4 when H-N and C-N are detected as 230VAC, both MAIN and
ROOM side turn on.
Procedure
1. Connect the cable to the appropriate terminals as shown on the
picture
2. Fix the cable with cable ties to the cable tie mountings to ensure
stress relief
NOTE:
1.The wiring of the thermostat should correspond to the settings
of the user interface. Refer to
10.7 Field setting/Room Thermostat.
2. Power supply of machine and room thermostat must be
connected to the same Neutral Line and (L2) Phase Line(for 3-
phase unit only).
There are three methods for connecting the thermostat cable (as
described in the picture above) and it depends on the application.
2. Room thermostat type 2(RT2)(Recommend wire connection
method): L N provide the power supply to the RT connector directly.
L connect from the unit main power supply port L of 1-phase power
supply , L2 of 3-phase power supply.
Maximum running current
Wiring size
Voltage
220~240VAC
0.2A
0.75mm
2
Type 2
Control port signal type
Maximum running current
Wiring size
Voltage
220~240VAC
0.2A
0.75mm
2
Type 2
Control port signal type
V.2
Summary of Contents for ETH-80VM
Page 4: ...4 1 2 1 3 1 1 1 1 1 1 1 2 3 1 1 0 1 0 1 0 Forma Nombre V 2...
Page 7: ...NOTA NOTA NOTA 404 502 1210 361 760 1404 760 361 1404 100mm 80mm 7 kW 10 12 14 16 kW 7 V 2...
Page 49: ...50 11 PRUEBA DE FUNCIONAMIENTO Y COMPROBACI N FINAL V 2...
Page 50: ...51 NOTA V 2...
Page 56: ...57 Equipos Monof sicos 5 y 7kW ANEXO 1 ESQUEMA EL CTRICO UNIDAD INTERIOR V 2...
Page 57: ...58 Equipos Monof sicos 10 a 16kW V 2...
Page 86: ...60mm B C A 25 V 2...
Page 176: ...V 2 WIRE CONTROL WITH WEEKLY PROGRAMMING OWNER S MANUAL MODEL ECRTH...
Page 199: ...V 2 www easelectric es...