1.7.21 PLOT
Description:
Plots a point at Current Position in Current Color.
Code:
26
hex,
38
dec
7
6
5
4
3
2
1
0
Byte 0: Command
See Also:
SET_XHY
,
SET_COLORH
Example:
The following sequence will put a blue point at (160, 117).
SET_COLORH
84
hex
BLUE_LSB
000
11111
bin
BLUE_MSB
00000
000
bin
SET_XHY
85
hex
0
0
dec (x MSB)
160
160
dec (x LSB)
0
0
dec (y MSB)
117
117
dec (y LSB)
PLOT
26
hex
PLOT