e z L C D -‐ 4 0 5
|
125
Rev.
© 2016 Earth Computers Tech. Inc.
In case of an
error
:
7
6
5
4
3
2
1
0
0
0
1
1
1
1
1
0
Byte 0:
3E
hex,
62
dec
The ezLCD response is sent through the same interface, which received the SD_FOLDER_DELETE
command.
Example:
The following sequence will delete folder MyDir from the root directory
SD_FOLDER_DELETE
4D
hex
'M'
4D
hex
'y'
79
hex
'D'
44
hex
'i'
69
hex
'r'
72
hex
NULL
0
hex
If the folder has successfully been deleted, the ezLCD responds with the following sequence:
3A
hex
In case of the failure, the following sequence will be sent by the ezLCD:
3E