16-3 Header Pins Settings
J1 Header Pin - Postion A, Factory default position
(pins 1 & 2 not linked) places TB1 Current sense
resistor in circuit.
J1 Header Pin - Postion B (pins 1 & 2 linked)
removes TB1 Current sense resistor out of circuit.
J2 Header Pin - Postion A, Factory default
position (pins 1 & 2 linked) removes power supply
TB Fault resistor & RLY 1-2 out of circuit.
J2 Header Pin - Postion B (pins 2 & 3 linked)
places power supply TB Fault resistor & RLY 1-2 in
Figure 8: J1 Header settings
Figure 9: J2 Header settings