Document No. BExL25D and BExL15D Danish    Issue E    (Two Sheets)      12-02-10                                                                                            (9)

 

INSTRUKTIONSMANUAL  (ATEX / IECEx)  (DNK) 

   BExL25D og BExL15D  Flammesikre højttalere 

 
 
 
 

 
 
2)   Mærkater 

 
Alle  enheder  har  en  klassificeringsmærkat,  der  bærer 

følgende vigtige oplysninger: 
 
Enhedstypenr.     

BExL25D   eller   BExL15D

 

 

Impedans: 

8 ohm eller 16 ohm 

      

 

100V eller 70V Linie 

 
Kode:              

Ex d IIC T4 for Ta –50°C to +55°C 

        Ex d IIB T4 for Ta –50°C to +70°C 

 

Certifikatnr.   

     KEMA 99ATEX6312 

 

 

IECEx KEM 10.0003

 

 

        

 

 

 

 
 

”Advarsler”

 

 

 

MÅ IKKE ÅBNES 

                  

   I EKSPLOSIV 

                  

GASATMOSFÆRE 

 

            DÆKBOLTE KLASSE A4-80 
 

    

BRUG VARMEBESTANDIGE KABLER OG PAKDÅSER 

 

     (Mærket 110ºC) VED OMGIVENDE TEMP. OVER 40ºC 

 

4)   Installationskrav 

 

 
Højttalere skal installeres i overensstemmelse med følgende 

eller tilsvarende standarder. 
 
EN60079-14:2008 

Elektriske installationer i sundheds 

IEC60079-14:2007 (Ed4) 

farlige områder (undtagen miner)

 

 

EN60079-10:2003 

Klassifikation af sundhedsfarlige om 

IEC60079-10:2008 (Ed1) 

råder

  

 
Installation bør kun udføres af kompetent personale og under 

iagttagelse af lokale regler. 

 

5)  Zone-, gasgruppe-, kategori- og temperatur- 
     klassifikation 

 

Enhederne kan installeres på områder med følgende forhold: 
  

Områdeklassifikation: 

 

Zone 1 

Eksplosiv gas- og luftblanding kan forekomme 
ved normal drift. 

Zone 2 

Eksplosiv  gas-  og  luftblanding  forekommer 
sandsynligvis ikke, og hvis det sker, vil det kun 

være for en kort tidsperiode. 

 

 
 

 

 

 
 
Gasgrupperinger: 

 

Gruppe IIA 

Propan 

Gruppe IIB 

Ethylen 

Gruppe IIC  < +55ºC 

Hydrogen og acetylen 

  

Udstyrskategori:

  

2G 

 

Temperaturklassifikation:                        

 

T1 

400

o

 C  

T2 

300

o

 C 

T3 

200

o

 C 

T4 

135

o

 C 

 

Omgivende temperatur: 

 

-50

°

C til +55

°

C Gasgrupperinger IIA, IIB og IIC 

  

-50

°

C til +70

°

C Gasgrupperinger IIA og IIB 

 
6)  Højttalerplacering og -montering

 

 
Se illustration A 
 

7) Sikkerhedsadvarsel (Elektrostatisk 
     sundhedsfare)

 

 

Delen med det akustiske horn er fremstillet af ABS-plast, og 
for at undgå en mulig ELEKTROSTATISK LADNING må en-

heden kun rengøres med en fugtig klud. 

 
8)  Adgang til flammesikker indkapsling

 

 

Se illustration B 

 
Bemærk,  at  de fire 

M6  skruer  er

 

klase  A4-80,  rustfri  stål, 

og  der  må  kun  anvendes  skruer  af  denne  kategori  på 
sounderne

.  Det  er  derfor  vigtigt,  at  skruerne  og  deres 

fjederskiver opbevares på et sikkert sted under installation. 

 
9)  Valg af strømforstærker 
 

Det er vigtigt, at højttalerne er forbundet til strømforstærkere, 

der  har  udgange  kompatible  med  den  type  højttaler,  der 
anvendes.  Højttalere  udstyret  med  en  100V  eller  70V 
ledningsafstemningstransformer  skal  være  forbundet  til  en 

strømforstærker  med  en  100V  eller  70V  ledningsudgang. 
Lavimpedans  højttalere  med 8 ohm eller  16 ohm skal  være 

forbundet 

til 

forstærkere 

med 

tilsvarende 

lav 

impedansudgang.  Når  kabelstørrelsen  vælges,  skal  den 

strøm, hver enhed trækker, antallet af højttalere på ledningen 
og længden af kabler tages i betragtning. 
 

Nedenstående tabel viser udvalget af højttalere: 

 

Enhedstype 

Input  

 

Watt 

 

Maks. 

 

 

 

 

 

 

I/P Volt

 

BExL25D  

100V Linie 

25W 

 

100V 

BExL25D  

70V Linie  

25W 

 

70V 

BExL25D  

8 ohm 

 

25W 

 

14,14V 

BExL25D  

16 ohm   

25W 

 

20V 

0518 

II  2G 

Epsilon x: 

Udstyrets gruppe 
og kategori: 

 

CE-mærke: 
Noteret 
myndighedsnr. 

Summary of Contents for BExL25D

Page 1: ...C Year of Construction Serial No i e 10 1L23000001 3 Type Approval Standards The loudspeakers have EC Type Examination and IECEx certificates issued by KEMA and have been approved to the following st...

Page 2: ...n place W hen replacing the flameproof cover casting ensure that it is square with the flameproof chamber casting before inserting Carefully push the cover in place allowing time for the air to be exp...

Page 3: ...hen the cable entry temperature may exceed 70 C and therefore suitable heat resisting cable glands must be used with a rated service temperature of at least 110 C If a high IP Ingress Protection ratin...

Page 4: ...citor and this should be taken into account when selecting the value of the end of line monitoring resistance The end of line monitoring resistor can be connected across the terminals on the end of li...

Page 5: ...y to occur and if it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Group IIC Up to 55 C only Hydrogen and Acetylene Equipment Category 2G Temperature Clas...

Page 6: ...ds Only cable glands approved for Ex d applications can be used which must be suitable for the type of cable being used and also meet the requirements of the Ex d flameproof installation standard EN60...

Page 7: ...roef aandraaien om vast te zetten Serrer la vis pour une fixation s re Zum Sichern Schraube anziehen Stringere la vite per il fissaggio Stram skruen for feste Aperte o parafuso para fixar Apriete el t...

Page 8: ...td Impress House Mansell Road Acton London W3 7QH sales e 2 s com Tel 44 0 208 743 8880 www e 2 s com Fax 44 0 208 740 4200 Document No BExL25D and BExL15D English Issue E Four Sheets 12 02 10 8 Wirin...

Page 9: ...synligvis ikke og hvis det sker vil det kun v re for en kort tidsperiode Gasgrupperinger Gruppe IIA Propan Gruppe IIB Ethylen Gruppe IIC 55 C Hydrogen og acetylen Udstyrskategori 2G Temperaturklassifi...

Page 10: ...es samt opfylde kravene i Ex d standard for flammesikker installation EN60079 14 2008 IEC60079 14 2007 SIKKERHEDSADVARSEL Hvis de h jtydende BExL25D h jttaler anvendes ved h je omgivende temperaturer...

Page 11: ...2 Ontplofbaar gas luchtmengsel is onwaarschijnlijk en indien dit ontstaat zal het waarschijnlijk slechts korte tijd aanwezig blijven Gasgroeperingen Groep IIA Propaan Groep IIB Ethyleen Groep IIC 55 C...

Page 12: ...rtels worden gebruikt die zijn goedgekeurd voor Ex d toepassingen geschikt zijn voor het bekabelingstype dat wordt gebruikt en voldoen aan de vereisten van de norm EN60079 14 2008 IEC60079 14 2007 ten...

Page 13: ...normale Zone 2 M lange d air et de gaz explosif ne pouvant pas survenir et qui dans le cas contraire serait pr sent que tr s bri vement Groupes de gaz Groupe IIA Propane Groupe IIB Ethyl ne Groupe IIC...

Page 14: ...cations Ex d peuvent tre utilis s et ils doivent tre ad quats pour le type de c ble utilis et r pondre aux exigences d installation d antid flagrant Ex d de norme EN60079 14 2008 IEC60079 14 2007 AVER...

Page 15: ...Luft Mischung vorliegen Zone 2 Explosive Gas Luft Mischung unwahrschein lich und sollte sie doch auftreten dann nur kurzfristig Gasgruppen Gruppe IIA Propan Gruppe IIB thylen Gruppe IIC 55 C Wasserst...

Page 16: ...abeltyp geeignet sein und zudem den Anforderungen der Ex d Norm zur Installation schwer entflammbarer Ger te EN60079 14 2008 IEC60079 14 2007 entsprechen SICHERHEITSHINWEIS Wenn die BExL25D High Outpu...

Page 17: ...esplosivo durante il normale funzionamento Zona 2 Non probabile che sia presente gas esplosivo e se esso dovesse essere presente potr esserlo solo per un breve periodo di tempo Gruppi di gas Gruppo I...

Page 18: ...ngressi per premistoppa con filettature M20 x1 5 Utilizzare solo premistoppa approvati per le applicazioni Ex d essi inoltre devono essere adeguati al tipo di cavo in uso e devono rispettare gli stand...

Page 19: ...losiv gass luft blanding som ikke vanligvis vil forekomme og om den gj r det kun vil forekomme i kort tid Gassgrupperinger Gruppe IIA Propan Gruppe IIB Etylen Gruppe IIC 55 C Hydrogen og acetylen Utst...

Page 20: ...elmuffer godkjent for Ex d bruk kan brukes og de m v re egnet for typen kabel som brukes samt overholde kravene i standarden for Ex d flammesikker installering EN60079 14 2003 IEC60079 14 2007 SIKKERH...

Page 21: ...va em funcionamento normal Zona 2 Improbabilidade de ocorr ncia de mistura gasosa explosiva mesmo que tal ocorra s ser por per odo curto Grupos de gases Grupo IIA Propano Grupo IIB Etileno Grupo IIC 5...

Page 22: ...ara aplica es prova de explos o que devem ser adequados ao tipo de cabo a ser usado e satisfazer tamb m os requisitos da norma EN60079 14 2008 IEC60079 14 2007 relativa instala o prova de fogo e de ex...

Page 23: ...s posible ocurra durante el funcionamiento normal Zona 2 Mezcla explosiva improbable de aire y gas que de producirse lo har s lo por breve tiempo Grupos de gas Grupo IIA Propano Grupo IIB Etileno Grup...

Page 24: ...cable aprobados para aplicaciones Ex d los cuales deben ser adecuados para el tipo de cable que se est utilizando adem s de satisfacer los requisitos de la norma EN 60079 14 2008 IEC60079 14 2007 para...

Page 25: ...al drift Zon 2 Explosiv gasblandning f rv ntas f rekomma s llan och d endast kortvarigt Explosionsgrupper Grupp IIA Propan Grupp IIB Etylen Grupp IIC 55 C V te och acetylen Kategori p utrustning 2G T...

Page 26: ...kabeling ngar med M20 x 1 5 g nga Endast kabelgenomf ringar godk nda f r Ex d bruk f r anv ndas Dessa m ste passa den typ av kabel som anv nds och dessutom uppfylla kraven f r explosionst t kapsling E...

Page 27: ...004 Directive 89 106 EEC Construction Products Directive CPD BExS110D24DC BExS120D24DC tones 2 3 9 15 16 17 only Notified Body for EC type Examination VdS Schadensverh tung GmbH Notified Body No 0786...

Reviews: