Document No. BExL25D and BExL15D Spanish    Issue E       (Two Sheets)          12-02-10                                                                             (23)

 

MANUAL DE INSTRUCCIONES (ATEX IECEx)    (ESP) 

Altavoces

 

 antideflagrantes 

BExL25D y BExL15D

 

 
 
 
 

 
2)   Marcas 

 
Todas  las  unidades  llevan  una  etiqueta  de clasificación con  
la siguiente información importante: - 

 
N° de tipo de unidad.     

 

BExL25D   o   BExL15D

 

 

Impedancia:    

 

 8 ohm o 16 ohm 

 

 

 

100V o 70V Línea 

 
Código   

Ex d IIC T4 for Ta –50°C to +55°C 

        

Ex d IIB T4 for Ta –50°C to +70°C 

 

N° de certificado

    

KEMA 99ATEX6312 

 

 

 

IECEx KEM 10.0003

 

 

        

 

 

 

 
 “Avisos”

 

NO ABRIR EN PRESENCIA DE GAS 
    ATMOSFÉRICO EXPLOSIVO 

 

PERNOS DE LA CUBIERTA CLASE A4-80 

 

UTILICE CABLES Y CASQUILLOS DE CABLE RESISTENTES AL 

CALOR (Clasificados a 110ºC) A TEMPERATURAS AMBIENTE 

SUPERIORES A 40ºC 

 

4)   Requisitos de instalación 

 

Las  altavoces  deben  instalarse  conforme  a  las  siguientes 
normas o sus equivalentes. 

 
EN60079-14:2008 

Instalaciones eléctricas en áreas  

IEC60079-14:2007 (Ed4)

    peligrosas (exceptuando minas)

 

 
EN60079-10:2003 

Clasificación de áreas peligrosas

 

IEC60079-10:2008 (Ed1) 
 

La instalación únicamente debe llevarse a cabo por parte de 
personal competente y debe observarse cualquier código de 

práctica local. 

 

5)  Clasificación de zonas, grupo de gas, categoría 
y temperatura 

 

Las unidades pueden instalarse en ubicaciones que cumplan 
las siguientes condiciones: - 

 

Clasificación del área: 

 

Zona 1 

Mezcla  explosiva  de  aire  y  gas  que  es  posible 

ocurra durante el funcionamiento normal. 

Zona 2 

Mezcla  explosiva  improbable  de  aire  y  gas  que, 
de producirse, lo hará sólo por breve tiempo. 

 
 
 

 

 

 
 
Grupos de gas: 

 

Grupo IIA 

Propano 

Grupo IIB 

Etileno 

Grupo IIC  < +55ºC 

Hidrógeno y acetileno  

  

Categoría de equipo:

 

2G 

 

Clasificación de temperatura: 

 

T1 

400

o

 C  

T2 

300

o

 C 

T3 

200

o

 C 

T4 

135

o

 C 

 

Rango de temperatura ambiente: 

 

  

-50

°

C a +55

°

C Grupos de gas IIA, IIB y IIC 

-50

°

C a +70

°

C Grupos de gas IIA y IIB 

 

6)  Ubicación y montaje de la altavoces

 

 
Véase el diagrama A 
 

7)  Aviso sobre seguridad (peligro electrostático)

 

 

La  sección  de  bocina  acústica  está  fabricada  de  plástico 
ABS,  por  lo  tanto,  a  fin  de  evitar  una  CARGA 

ELECTROSTÁTICA,  la  unidad  únicamente  debe  limpiarse 
con un paño húmedo. 

 
8)  Acceso a la caja antideflagrante

 

 

Véase el diagrama B 
 

Obsérvese  que  los  cuatro 

tornillos

 

M6  son  de  acero 

inoxidable  de  clase  A4-80  y  que  con  estas  sondas 
acústicas  únicamente  deben  utilizarse  tornillos  de  esta 

categoría. 

Por ello,  es  importante  que estos  tornillos,  y  las 

arandelas elásticas se guarden en un lugar seguro durante la 

instalación. 
 

 
9)  Selección de amplificador de potencia 
 

Es  importante  conectar  los  altavoces    a  amplificadores  de 
potencia  que  tengan  salidas  compatibles  con  el  tipo  de 

altavoz  que  se  está  utilizando.  Los  altavoces que  llevan  un 
transformador de adaptación de línea de 100V o 70V deben 

conectarse a un amplificador de potencia con una salida de 
línea de 100V o 70V. Los altavoces de baja impedancia de 8 
ó  16  ohmios  deben  conectarse  a  amplificadores  con  una 

salida de baja impedancia adecuada. Cuando se seleccione 
el  tamaño  de  cable  ,  debe  considerarse  la  corriente  que 

extrae  cada  línea,  el  número  de  altavoces  en  la  línea  y  la 
longitud de las secciones de cable. 

 
 

 

0518 

II 2G 

Epsilon x: 

Categoría y grupo 
de equipamiento:

 

 

Marca CE: 
N° de cuerpo de 

notificación 
 

Summary of Contents for BExL25D

Page 1: ...C Year of Construction Serial No i e 10 1L23000001 3 Type Approval Standards The loudspeakers have EC Type Examination and IECEx certificates issued by KEMA and have been approved to the following st...

Page 2: ...n place W hen replacing the flameproof cover casting ensure that it is square with the flameproof chamber casting before inserting Carefully push the cover in place allowing time for the air to be exp...

Page 3: ...hen the cable entry temperature may exceed 70 C and therefore suitable heat resisting cable glands must be used with a rated service temperature of at least 110 C If a high IP Ingress Protection ratin...

Page 4: ...citor and this should be taken into account when selecting the value of the end of line monitoring resistance The end of line monitoring resistor can be connected across the terminals on the end of li...

Page 5: ...y to occur and if it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Group IIC Up to 55 C only Hydrogen and Acetylene Equipment Category 2G Temperature Clas...

Page 6: ...ds Only cable glands approved for Ex d applications can be used which must be suitable for the type of cable being used and also meet the requirements of the Ex d flameproof installation standard EN60...

Page 7: ...roef aandraaien om vast te zetten Serrer la vis pour une fixation s re Zum Sichern Schraube anziehen Stringere la vite per il fissaggio Stram skruen for feste Aperte o parafuso para fixar Apriete el t...

Page 8: ...td Impress House Mansell Road Acton London W3 7QH sales e 2 s com Tel 44 0 208 743 8880 www e 2 s com Fax 44 0 208 740 4200 Document No BExL25D and BExL15D English Issue E Four Sheets 12 02 10 8 Wirin...

Page 9: ...synligvis ikke og hvis det sker vil det kun v re for en kort tidsperiode Gasgrupperinger Gruppe IIA Propan Gruppe IIB Ethylen Gruppe IIC 55 C Hydrogen og acetylen Udstyrskategori 2G Temperaturklassifi...

Page 10: ...es samt opfylde kravene i Ex d standard for flammesikker installation EN60079 14 2008 IEC60079 14 2007 SIKKERHEDSADVARSEL Hvis de h jtydende BExL25D h jttaler anvendes ved h je omgivende temperaturer...

Page 11: ...2 Ontplofbaar gas luchtmengsel is onwaarschijnlijk en indien dit ontstaat zal het waarschijnlijk slechts korte tijd aanwezig blijven Gasgroeperingen Groep IIA Propaan Groep IIB Ethyleen Groep IIC 55 C...

Page 12: ...rtels worden gebruikt die zijn goedgekeurd voor Ex d toepassingen geschikt zijn voor het bekabelingstype dat wordt gebruikt en voldoen aan de vereisten van de norm EN60079 14 2008 IEC60079 14 2007 ten...

Page 13: ...normale Zone 2 M lange d air et de gaz explosif ne pouvant pas survenir et qui dans le cas contraire serait pr sent que tr s bri vement Groupes de gaz Groupe IIA Propane Groupe IIB Ethyl ne Groupe IIC...

Page 14: ...cations Ex d peuvent tre utilis s et ils doivent tre ad quats pour le type de c ble utilis et r pondre aux exigences d installation d antid flagrant Ex d de norme EN60079 14 2008 IEC60079 14 2007 AVER...

Page 15: ...Luft Mischung vorliegen Zone 2 Explosive Gas Luft Mischung unwahrschein lich und sollte sie doch auftreten dann nur kurzfristig Gasgruppen Gruppe IIA Propan Gruppe IIB thylen Gruppe IIC 55 C Wasserst...

Page 16: ...abeltyp geeignet sein und zudem den Anforderungen der Ex d Norm zur Installation schwer entflammbarer Ger te EN60079 14 2008 IEC60079 14 2007 entsprechen SICHERHEITSHINWEIS Wenn die BExL25D High Outpu...

Page 17: ...esplosivo durante il normale funzionamento Zona 2 Non probabile che sia presente gas esplosivo e se esso dovesse essere presente potr esserlo solo per un breve periodo di tempo Gruppi di gas Gruppo I...

Page 18: ...ngressi per premistoppa con filettature M20 x1 5 Utilizzare solo premistoppa approvati per le applicazioni Ex d essi inoltre devono essere adeguati al tipo di cavo in uso e devono rispettare gli stand...

Page 19: ...losiv gass luft blanding som ikke vanligvis vil forekomme og om den gj r det kun vil forekomme i kort tid Gassgrupperinger Gruppe IIA Propan Gruppe IIB Etylen Gruppe IIC 55 C Hydrogen og acetylen Utst...

Page 20: ...elmuffer godkjent for Ex d bruk kan brukes og de m v re egnet for typen kabel som brukes samt overholde kravene i standarden for Ex d flammesikker installering EN60079 14 2003 IEC60079 14 2007 SIKKERH...

Page 21: ...va em funcionamento normal Zona 2 Improbabilidade de ocorr ncia de mistura gasosa explosiva mesmo que tal ocorra s ser por per odo curto Grupos de gases Grupo IIA Propano Grupo IIB Etileno Grupo IIC 5...

Page 22: ...ara aplica es prova de explos o que devem ser adequados ao tipo de cabo a ser usado e satisfazer tamb m os requisitos da norma EN60079 14 2008 IEC60079 14 2007 relativa instala o prova de fogo e de ex...

Page 23: ...s posible ocurra durante el funcionamiento normal Zona 2 Mezcla explosiva improbable de aire y gas que de producirse lo har s lo por breve tiempo Grupos de gas Grupo IIA Propano Grupo IIB Etileno Grup...

Page 24: ...cable aprobados para aplicaciones Ex d los cuales deben ser adecuados para el tipo de cable que se est utilizando adem s de satisfacer los requisitos de la norma EN 60079 14 2008 IEC60079 14 2007 para...

Page 25: ...al drift Zon 2 Explosiv gasblandning f rv ntas f rekomma s llan och d endast kortvarigt Explosionsgrupper Grupp IIA Propan Grupp IIB Etylen Grupp IIC 55 C V te och acetylen Kategori p utrustning 2G T...

Page 26: ...kabeling ngar med M20 x 1 5 g nga Endast kabelgenomf ringar godk nda f r Ex d bruk f r anv ndas Dessa m ste passa den typ av kabel som anv nds och dessutom uppfylla kraven f r explosionst t kapsling E...

Page 27: ...004 Directive 89 106 EEC Construction Products Directive CPD BExS110D24DC BExS120D24DC tones 2 3 9 15 16 17 only Notified Body for EC type Examination VdS Schadensverh tung GmbH Notified Body No 0786...

Reviews: