ELEC
7 - 20
CHARGING SYSTEM
Positive tester probe
white
Negative tester probe
white/Red
• Measure the charging coil resistance.
Charging coil resistance
0.72 ~ 0.97 Ω at 20°C
• Is the charging coil OK?
5. Wiring
• Check the wiring connections of the entire
charging system.
Refer to “CIRCUIT DIAGRAM”.
• Is the charging system’s wiring properly
connected and without defects?
Replace the char-
ging coil assembly.
Properly connect or
repair the charging
system’s wiring.
Replace the rectifier/
regulator.
YES
NO
YES
NO