![E-TON Yukon II Service Manual Download Page 147](http://html1.mh-extra.com/html/e-ton/yukon-ii/yukon-ii_service-manual_3181419147.webp)
5 - 7
2. Adjust:
Throttle cable free play (at the flange
of the throttle grip)
5 ~ 10 mm (0.20 ~ 0.39 in)
18.8 mm (0.74 in)
Refer to “ADJUSTING THE THROTTLE CABLE
FREE PLAY” in chapter 3.
•
throttle cable free play
MEASURING AND ADJUSTING THE FUEL
1. Measure:
• fuel level
Out of specification → Adjust.
a. Stand the machine on a level surface.
b. Install the fuel level gauge onto the fuel
drain pipe
.
c. Loosen the fuel drain screw
.
d. Hold the fuel level gauge vertically next to
the line on the float chamber.
e. Measure the fuel level .
Fuel level
(above the float chamber mating
surface)
1
2
3
a
a
2. Adjust:
a. Remove the carburetor assembly.
b. Check the needle valve seat and needle
valve.
c. If either is worn, replace them as a set.
d. If both are fine, adjust the float level by
slightly bending the float tang.
e. Install the carburetor assembly.
f. Measure the fuel level again .
g. Repeat steps (a) to (f) until the fuel level is
within specification.
a
•
fuel level
CARB
CARBURETOR
LEVEL
1
2
3
a