e-ride Industries
Page 58
6.1.2
Battery Pack Inspection
Inspection Procedure:
1.
Make sure main battery disconnect has been shut off and access the batteries as described
above.
2.
Inspect for any loose connections by wiggling the top post battery cables where they
attach to the top of the battery. If you find any signs of a loose cable connection, they
must be tightened by a trained professional before the main disconnect switch is turned
back on. *Note: The main battery disconnect does not disconnect power from battery to
battery.
3.
Inspect for any acid spills or corrosion to the battery posts or cables. If corrosion exists,
the aluminum or metal components will turn white in color. All acid or vulnerable metals
must be cleaned appropriately by a trained professional before the main disconnect
switch is turned back on.