1  General

This operation manual serves for ensuring proper handling and optimal functioning of the device. The 

operation manual shall be read before commissioning the equipment and it shall be provided to all staff 

involved in transport, installation, operation, maintenance and repair.

The operation manual may not be used for the purposes of competition without the written consent of 

E+E Elektronik® and may not be forwarded to third parties. Copies may be made for internal purposes. 

All information, technical data and diagrams included in these instructions are based on the information 

available at the time of writing.

Intended use

The EE211 is intended for the measurement of relative humidity (RH) and temperature (T) in  

environment with continuous high humidity. The use of the EE211 other than described in this manual is 

not recommended. 

The manufacturer cannot be held responsible for damages as a result of incorrect handling, installation 

and maintenance of the device. Unauthorized modifications of the product lead to loss of all warranty 

claims. The device may only be powered with separated extra-low voltage (SELV).

Disclaimer

The manufacturer or his authorized agent can be only be held liable in case of willful or gross  

negligence. In any case, the scope of liability is limited to the corresponding amount of the order issued 

to the manufacturer. The manufacturer assumes no liability for damages incurred due to failure to 

comply with the applicable regulations, operating instructions or the operating conditions. Consequential 

damages are excluded from the liability.

1.1  Explanation of Symbols

This symbol indicates safety information.

It is essential that all safety information is strictly observed. Failure to comply with this information can 

lead to personal injuries or damage to property. E+E Elektronik® assumes no liability if this happens.

This symbol indicates instructions.

The instructions shall be observed in order to reach optimal performance of the device.

1.1.1  General Safety Instructions

•  The sensor and mainly the sensing head of the probes shall not be exposed 

to extreme mechanical stress.

•  Installation, electrical connection, maintenance and commissioning shall be performed by  

qualified personnel only.

•  Use the EE211 only as intended and observe all technical specs.

•  Make sure that the T Probe is properly connected. The absence of the T probe forces the analogue 

outputs into the upper limitation.

•  The sensor must be operated with the filter caps on at all times. Do not touch the sensors inside the 

sensing head.

•  While replacing the filter cap (because of pollution for instance) against an original spare one please 

take very good care to not touch the sensors.

1.2  Environmental Aspects

Products from E+E Elektronik® are developed and manufactured observing of all relevant requirements 

with respect to environment protection. Please observe local regulations for the device disposal.

For disposal, the individual components of the device must be separated according to local recycling 

regulations. The electronics shall be disposed of correctly as electronics waste.

Summary of Contents for EE211

Page 1: ...BA_EE211_e V1 3 technical data are subject to change Operation Manual EE211 HEATED HUMIDITY TEMPERATURE SENSOR...

Page 2: ...equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmf...

Page 3: ...7 3 6 1 Examples 7 4 Assembly and Installation 7 5 Setup 8 5 1 EE PCS Product Configuration Software 8 5 2 Digital Interface RS485 with Modbus RTU Protocol 8 5 2 1 Hardware Bus Termination 8 5 2 2 Add...

Page 4: ...ed due to failure to comply with the applicable regulations operating instructions or the operating conditions Consequential damages are excluded from the liability 1 1 Explanation of Symbols This sym...

Page 5: ...hem clearly as faulty A faulty device may only be investigated and possibly repaired by qualified trained and authorized staff If the fault cannot be fixed the device shall be removed from the system...

Page 6: ...ensing head E E proprietary coating of the sensing element and sealed solder pads minimize the impact of corrosive agents Maximum humidity of 76 RH at the sensor eliminates the drift caused by exposur...

Page 7: ...using the EE PCS Product Configuration Software and the optio nal USB configuration adapter HA011066 3 6 1 Examples Factory setup voltage output 0 5 V or 0 10 V corresponds to 0 100 RH After switching...

Page 8: ...the USB configura tion adapter HA011066 PC HA011066 Fig 3 Configuration adapter 5 1 EE PCS Product Configuration Software 1 Download the EE PCS Product Configuration Software from www epluse com confi...

Page 9: ...set via 1 EE PCS Product Configuration Software and the appropriate configuration cable 2 Modbus protocol in the register 60001 0x00 and 60002 0x01 See Application Note Modbus AN0103 available on www...

Page 10: ...ter number1 Dec Register address2 Hex Parameter name 60001 0x00 Slave ID5 modbus address 60002 0x01 Modbus protocol settings6 Tab 5 Integer 16 bit read and write register INFO read register Function c...

Page 11: ...dress Hi Starting address Lo No of register Hi No of register Lo CRC Request Hex EF 03 00 19 00 02 EB 7B Response Hex EF 03 04 38 5F 41 D5 0A E3 Modbus ID address Function code Byte count Register 1 v...

Page 12: ...roves the measurement accuracy of a device The specimen is compared with the reference and brought in line with it An adjustment can be followed by a calibration which documents the accuracy of the ad...

Page 13: ...e a Windows PC using the EE PCA product configuration adapter and the cable HA011057 see data sheet EE PCA EE PCS free download from www epluse com configurator shall be installed on the PC Start EE P...

Page 14: ...lsoure material Polycarbonate UL94V 0 with Display UL94HB approved T probe material Stainless steel 1 4571 Protection class IP65 NEMA 4 Cable gland M20 x 1 5 Electromagnetic compatibility EN61326 1 In...

Page 15: ...15 Operating manual EE211 Heated humidity and temperature sensor...

Page 16: ...0 6460 Office Stuttgart Tel 49 151 538 37 500 E E Elektronik Italy info epluse it Tel 39 02 2707 86 36 E E Elektronik France info epluse fr Tel 33 4 74 72 35 82 E E Elektronik USA office epluse com Of...

Reviews: