43
GAS TYPE CONVERSION
: Gas type conversion from LPG to natural gas or from natural gas toLPG
must be carried out only by qualified person.
- Gas type conversion can be divided in 3 sections: replacement of the gas valve and gas restrictor,
installation of the BCC and combustion check.
- Conversion kits comprise the following items:
- Gas valve
- Gas restrictor
- BCC
- Conversion label
-Conversion kits:
- LPG to Natural Gas for CP 24 HST
- LPG to Natural Gas for CP 30 HST
- Natural Gas to LPG for CP 24 HST
- Natural Gas to LPG for CP 30 HST
Replacement Of The Gas Valve And Gas Restrictor
WARNING: Keep the gas inlet valve and electricity supply closed during
replacement of the gas valve and gas restrictor.
- Shut off the boiler by turning the ON/OFF switch to OFF position and turn the gas inlet valve off.
- Undo the 2 screws which are located on the lower edge to remove the front panel.
- Undo the 2 screws which are located on the corners of the control panel.
- Pull the control panel outwards.
- Undo the 6 screws which are located around the body to remove the combustion body cover.
- Disconnect the electricity plug and the feedback connection from the gas valve.
- Replace the gas valve and gas restrictor according to fig. 32.
- Reassemble in the reverse order.
Table 6
Gas Restrictors
CP 24 HST - Natural Gas
∅
5,9 mm
CP 24 HST – LPG
∅
4,8 mm
CP 30 HST - Natural Gas
∅
6,7 mm
CP 30 HST – LPG
∅
5,5 mm
1
Summary of Contents for Confeo Premix CP 24 HST
Page 10: ...9 fig 1 agram...
Page 12: ...11 b a...
Page 19: ...18 fig 9...
Page 20: ...19 fig 10 7 B for CP 24 HM P 4 m for CP 30 HM P and 5 m for CP 35 HM P models...
Page 21: ...20 fig 11...
Page 22: ...21 h fig 13 a...
Page 23: ...22 fig 13...
Page 24: ...23 fig 14...
Page 25: ...24 fig 15...
Page 41: ...41 a Flow Adjusment b Offset Adjustment fig 30 fig 31...