40
Jbus
MODbus
Description
Display
Attribute
Address
Address
Code
259
258
Decimal point position
R
Range:
0 = No decimal figure
1 = One decimal figure
2 = Two decimal figures
3 = Three decimal figures
4 = Four decimal figures
Note: Decimal figure assigned to:
- Initial scale readout
- Final scale readout
- Input variable without filter
- Filtered input variable
- Peak max value
- Peak min value
- Full scale transducer calibration value
- Tare calibration value
- Alarm 1 threshold
- Alarm 2 threshold
260
259
Initial scale readout RDM
261
260
Final scale readout RDM
(“F.S.U.”)
RDM
263
262
Multiplier R
Range: 1 - 10 - 100
Note: Multiplier assigned to:
- Initial scale readout
- Final scale readout
- Input variable without filter
- Filtered input variable
- Peak max value
- Peak min value
- Full scale transducer calibration value
- Tare calibration value
- Alarm 1 threshold
- Alarm 2 threshold
264
263
Display filter time constant
(“F.t.C.”)
R
Range:
1 = 400 ms filter time constant
2 = 1 s filter time constant
3 = 2 s filter time constant
4 = 3 s filter time constant
5 = 4 s filter time constant
6 = 5 s filter time constant