![Dynatronix DHP12-1500 Operating Manual Download Page 47](http://html.mh-extra.com/html/dynatronix/dhp12-1500/dhp12-1500_operating-manual_2549220047.webp)
Diamond 36kW Manual
Dynatronix, Inc.
198-1600-00 Rev F
Page 47 of 146
As with all output configurations the power supply operates in a cross over regulation mode. See
6.8 Setting Adjustment and Regulation Modes
for details on regulation modes.
To configure the supply for DC output set the output type
to “DC” in the output setup menu. Use
the following procedure to configure the supply for DC output. See
details on the output setup menu.
1)
Enter the “Unit Setup Menu” by pressing and holding both encoder switches until the
display shows “Unit” “SEt” (see
for details).
2) Rotate the curr
ent encoder until the display shows “SEt” “OUt”. Then press the
voltage encoder switch
to enter the “Output Setup Menu”.
3)
From the “Output Setup Menu” rotate the current encoder until the display shows
“OUt” “tyPE”. Then press the voltage encoder switch to view and change the output
type.
4) The output type
is indicated by “tyPE” on the top display and the selected output
type on the bottom display. The SET lamp is blinking on and off to indicate that a
setting is displayed. Rotate the current encoder to change the output
type to “dC”.
Once the desired output type is selected press the voltage encoder switch to accept
the value and return to the “Output Setup Menu”.
5)
From the “Output Setup Menu” rotate the current encoder until the display shows
“OUt” “End”. Then press the voltage encoder switch to exit the “Output Setup Menu”
and return to the “Unit Setup Menu”.
6) If any settings were changed you will be prompted to store the changes. Select
“yES” to accept the changes or “no” to cancel the changes.
7) From th
e “Unit Setup Menu” rotate the current encoder until the display shows “SEt”
“End”. Press the voltage encoder switch to exit the “Unit Setup Menu”.
NOTE:
The DC voltage setting and current setting can be changed from the meter display. See
6.7:Current and Voltage Settings
for details on adjusting these settings.
6.4.4. Pulsed Output
When the power supply is configured for pulsed output the output of the power supply pulses on
and off by pulsing the current setting on and off. The DC voltage setting, the peak current setting,
and the pulse on and off times are all configurable. The peak current setting is the current setting
that is used during the pulse on time. During the pulse off time the current setting is zero. The
voltage setting remains constant.
As with all output configurations the power supply operates in a cross over regulation mode. See
6.8 Setting Adjustment and Regulation Modes
for details on regulation modes.
To configure the supply for pulse output set the output type
to “Pulse” in the output setup menu.
Use the following procedure to configure the supply for pulse output. See
for details on the output setup menu.
1)
Enter the “Unit Setup Menu” by pressing and holding both encoder switches until the
display sho
for details).
2)
Rotate the current encoder until the display shows “SEt” “OUt”. Then press the
voltage encoder switch to enter t
he “Output Setup Menu”.