7)
From the “Cycle Setup Menu” rotate the current encoder until the display shows
“CyCL” “dEC”. Then press the voltage encoder switch to view and change the cycle
time decimal point location.
8) The cycle time decimal point location is indicate
d by “dEC” on the top display and
the selected decimal point location on the bottom display. The SET lamp is blinking
on and off to indicate that a setting is displayed. Rotate the current encoder to
select the desired decimal point location. The decimal point location affects the
resolution of the cycle preset time setting and also affects the maximum possible
cycle preset time setting. The maximum cycle time is 99999999, or 9999999.9, or
999999.99, or 99999.999, depending on where the decimal location is set to. Once
the desired decimal location is set press the voltage encoder switch to accept the
setting and return to the “Cycle Setup Menu”.
9)
From the “Cycle Setup Menu” rotate the current encoder until the display shows
“CyCL” “SEt”. Then press the voltage encoder switch to view and change the cycle
preset time.
10) When the cycle preset time is displayed the top display will indicate the units of the
cycle preset and which half of the preset is being displayed (the preset value has
eight digits, but only four can be displayed at a time). The first part of the message
indicates the units. For an RTC cycle with units set to minutes the top display will
show “SEt min”. An RTC cycle with units set to hours will display “SEt hr” on the top
display. Likew
ise an ATC cycle could display “SEt Amp min” or “SEt Amp hr” on the
top display. The last part of the message indicates if the four most significant digits
(“Hi”) or the four least significant digits (“Lo”) of the preset are being displayed.
Rotate the v
oltage encoder to switch between the upper (“Hi”) and lower (“Lo”) four
digits of the preset. The bottom display will show the currently selected half of the
cycle preset time. The decimal place and maximum allowed setting will be
dependent on the decimal setting made in the preceding steps. The SET lamp is
blinking on and off to indicate that a setting is displayed. Rotate the current encoder
to change the selected digit (blinking digit). Each press of the current encoder
selects the next digit. Rotate the voltage encoder to change between the upper
(“Hi”) and lower (“Lo”) four digits of the preset. Once the desired cycle preset is set
press the voltage encoder switch to accept the setting and return to the “Cycle Setup
Menu”.
11)
From the “Cycle Setup Menu” rotate the current encoder until the display shows
“CyCL” “End”. Then press the voltage encoder switch to exit the “Cycle Setup
Menu” and return to the “Unit Setup Menu”.
12) If any cycle settings were changed you will be prompted to store the changes.
Select “yES” to accept the changes or “no” to cancel the changes.
13)
From the “Unit Setup Menu” rotate the current encoder until the display shows “SEt”
“End”. Press the voltage encoder switch to exit the “Unit Setup Menu”.
6.4.3. DC Output
When the power supply is configured for DC output the output of the power supply will regulate to
a constant current or voltage based on the current and voltage settings and the load connected to
the power supply.