Diamond 36kW Manual
Dynatronix, Inc.
198-1600-00 Rev F
Page 139 of 146
23
Inverter
Control
(0 to n)
The inverter configuration and the
process control configuration do
not match for inverter module A.
Cycle power. If fault continues
report to Dynatronix, Inc.
YES
YES
24
Inverter
Control
(0 to n)
The inverter configuration and the
process control configuration do
not match for inverter module B.
Cycle power. If fault continues
report to Dynatronix, Inc.
YES
YES
25
Inverter
Control
(0 to n)
Primary heat sink over
temperature condition on module
A.
Fault auto clears when the
primary heat sink temperature
drops to a safe level.
YES
YES
26
Inverter
Control
(0 to n)
Primary heat sink over
temperature condition on module
B.
Fault auto clears when the
primary heat sink temperature
drops to a safe level.
YES
YES
27
Inverter
Control
(0 to n)
Secondary heat sink over
temperature condition on module
A.
Fault auto clears when the
secondary heat sink
temperature drops to a safe
level.
YES
YES
28
Inverter
Control
(0 to n)
Secondary heat sink over
temperature condition on module
B.
Fault auto clears when the
secondary heat sink
temperature drops to a safe
level.
YES
YES
29
Output
Channel
(0 to n)
Inverter output inhibit/interlock
was triggered during operate
mode causing the output to
become disabled and change the
controller state to standby.
Manually clear the fault.
Operate mode will be allowed
when the inverter output
inhibit/interlock becomes
inactive.
YES
YES
30
Inverter
Control
(0 to n)
Transformer one over current fault
on output module A.
Turn off power and report to
Dynatronix, Inc.
YES
YES
31
Inverter
Control
(0 to n)
Transformer one over current fault
on output module B.
Turn off power and report to
Dynatronix, Inc.
YES
YES
32
Inverter
Control
(0 to n)
Transformer two over current fault
on output module A.
Turn off power and report to
Dynatronix, Inc.
YES
YES
33
Inverter
Control
(0 to n)
Transformer two over current fault
on output module B.
Turn off power and report to
Dynatronix, Inc.
YES
YES
34
Inverter
Control
(0 to n)
Bus balance fault on output
module A.
Cycle power. If fault continues
report to Dynatronix, Inc.
YES
YES
35
Inverter
Control
(0 to n)
Bus balance fault on output
module B.
Cycle power. If fault continues
report to Dynatronix, Inc.
YES
YES
36
Inverter
Control
(0 to n)
PFC boost time out fault on output
module A.
Cycle power. If fault continues
report to Dynatronix, Inc.
YES
YES
37
Inverter
Control
(0 to n)
PFC boost time out fault on output
module B.
Cycle power. If fault continues
report to Dynatronix, Inc.
YES
YES
38
Inverter
Control
(0 to n)
Primary connection (internal
connection) fault on output
module A.
Cycle power. If fault continues
report to Dynatronix, Inc.
YES
YES
39
Inverter
Control
(0 to n)
Primary connection (internal
connection) fault on output
module B.
Cycle power. If fault continues
report to Dynatronix, Inc.
YES
YES