Maintenance - 2000h
4812160801_D.pdf
2018-12-17
Hydraulic reservoir - Check/venting
Figure. Engine compartment, right side
1. Hydraulic fluid tank cap
1
Unscrew and make sure that the reservoir cap is not
blocked. Air must have unobstructed passage through
the cap in both directions.
If blocked in either direction, clean with a little diesel oil
and blow with compressed air until unblocked or
replace the cap with a new one.
Wear eye protectors and gloves when working
with compressed air.
Wear eye protectors and gloves when working
with compressed air.
Fig. Engine compartment, right side
1. Sight glass
1
Check the hydraulic oil level in the sight glass (1) and
top off where necessary. See under the heading
‘Every 10 hours of operation’.