2
Installation and Testing
2.1
DX-GB Mounting
74 mm
2.91"
115 mm
4.53"
M5 x 10mm or #10/32 x 0.39" (max)
TYP x 3
The DX-GB must be mounted with the lid-down and at a minimum incline of
5° from horizontal.
GBK64048
: Issue 1 – June 2007
10
5° min, 90° max
The position and orientation must give maximum mechanical protection to
the DX-GB.
Mount the DX-GB out of the path of water splashes from the wheels or the
motor housing. Make sure the DX GB will never be immersed in water.
Protect the front (connector panel) of the DX-GB from direct splashing.
Failure to adhere to the mounting orientations specified might lead to
water ingress, which can result in system malfunction and long-term
damage to the unit.