EC-2000-CES MANUAL
30
13.
ANGLE #6
14.
SPEED #6
15.
CREEP ANGLE
16.
CREEP SPEED
If the control is in single stroke mode when it passes the creep angle, it will run at the
creep speed
Programmed Speed for Creep Speed:
0 to Max SPM
17.
STOP ANGLE
If the control is in single stroke mode when it passes the stop angle, it will conduct a
normal stop
18.
RESOLVER OFFSET
Enter degrees to correct resolver reading to actual press position
0 – 360 degrees
19.
RESOLVER DIR REV
o
ENABLE
o
DISABLE (default)
20.
GEAR RATIO
Enter Gear Ratio from Press Drive to Press
Default = 25
8.6
Menu G: FAULT
1.
CURRENT FAULT
Allows the user to see the current fault (read only).
2.
PRIOR FAULT #1
Allows the user to see the previous fault (read only).
3.
PRIOR FAULT #2
Allows the user to see the second previous fault (read only).
4.
PRIOR FAULT #3
Allows the user to see the third previous fault (read only).
Summary of Contents for 015-000248-2002
Page 7: ...EC 2000 CES MANUAL 7 Figure 1 Eddy Current Drive Block Diagram ...
Page 8: ...EC 2000 CES MANUAL 8 Figure 2 EC 2000 CES Keypad Display ...
Page 12: ...EC 2000 CES MANUAL 12 ...
Page 16: ...EC 2000 CES MANUAL 16 Figure 4 Keypad Cutout Template to Scale Inches ...
Page 17: ...EC 2000 CES MANUAL 17 Figure 5 Keypad Dimensions to Scale ...