On the control keypad, enter the test (local control) mode as follows:
1.
Press the “enter” key.
2.
Use the “down” arrow until you reach “SERIAL OPTIONS”
3.
Press the “enter” key.
4.
Use the “”up” arrow key until you reach “EC-2000 MENUS”
5.
Press the “enter” key
6.
Use the “up” arrow to change from disabled to enabled.
7.
Press the “enter” key
8.
Press the “exit” key
9.
Use the “”up” arrow key until you reach “EC-2000 OUTPUT ON”
10.
Press the “enter” key
11.
Use the “up” arrow to change from disabled to enabled.
12.
Press the “enter” key
13.
Press the “exit” key 3 times
14.
Press the “p1” key -- This allows you to directly program the clutch control board.
15.
Press the “enter” key
16.
Use the “up” arrow key until you reach “CONTROL SETUP”
17.
Press the “enter” key
18.
Use the “up” arrow until you reach “LOCAL\REM ENABLE”
19.
Press the “enter” key
20.
Use the “up” arrow to change from disabled to enabled.
21.
Press the “enter” key
22.
Press the “exit” key 3 times
23.
Press the “local-remote” key. The control can now be operated from the keypad.
24.
Press the “set point” key.
25.
Use the “up” arrow to set the set point to 1000.
26.
Press the “set point” key
27.
Connect a clip on DC Ammeter to one of the clutch leads.
28.
Press the “run” key to energize the clutch. Press the “stop” key to de-energize the clutch.
The current should ramp up and limit at the set current limit of the control.
29.
Press the “stop” key. The brake will energize for the period set under D. BRAK
PERFORMANCE” 10. BRK OFF DEL SEC.
30.
If the currents limit properly the test is complete. Go to Step 36. If not then you will need
to calibrate the meter readings to match the actual currents.
31.
To calibrate the currents make a note of the value reached during the test.
32.
Press “p1” to return to the brake programing mode.
33.
To calibrate the clutch amps go to Menu A CONTROL SETUP Item 16 CLUT CURR SCALE.
The default value is 100% raise this value to lower the actual amps or lower the value to
increase the actual amps. Example:
34.
Current Limit 100A.
35.
Actual Current 120A
36.
100% X 120 / 100 = 120% Is the correct Setting
Summary of Contents for 015-000248-2002
Page 7: ...EC 2000 CES MANUAL 7 Figure 1 Eddy Current Drive Block Diagram ...
Page 8: ...EC 2000 CES MANUAL 8 Figure 2 EC 2000 CES Keypad Display ...
Page 12: ...EC 2000 CES MANUAL 12 ...
Page 16: ...EC 2000 CES MANUAL 16 Figure 4 Keypad Cutout Template to Scale Inches ...
Page 17: ...EC 2000 CES MANUAL 17 Figure 5 Keypad Dimensions to Scale ...