![Dynamatic 015-000248-2002 Instruction Manual Download Page 34](http://html.mh-extra.com/html/dynamatic/015-000248-2002/015-000248-2002_instruction-manual_2547975034.webp)
EC-2000-CES MANUAL
34
19.
UND SPD TRIP %
Percentage of max brake current for on too long timer
Fault 313
Default = 30 %
20.
FDBK FLT TIME
Tachometer Feedback Fault Timer
Fault 205
Default = 2000 MS
21.
FDBK FLT CL CUR %
Tachometer Feedback Fault % FL Amps
Fault 205
Default = 30 %
22.
RESOLV-TACH-UPD
Update Time for Resolver Speed Update
Default = 100 MS
23.
SERIAL COMM FAULT
Timer For EC-2000 Communication Fault
Fault 231
Default = 5000 MS
24.
MISSING STPT TIME
Timer For EC-2000 to acknowledge a set point. If the control fails to receive a set point
after a run or inch command is issued this fault will be issued.
Fault 204
Default = 2000 MS
8.8 Menu I POSITION ERROR SETUP
1.
TOP STOP ERROR
If the error in stopping at the programmed stop angle exceeds this value +/- Fault will
be set
Fault 224
Default = 30 degrees